Reduced-Force Closed Trocar Entry Technique: Analysis of Trocar Insertion Force Using a Mechanical Force Gauge

نویسندگان

  • James Fanning
  • Manish Shah
  • Bradford Fenton
چکیده

BACKGROUND AND OBJECTIVES Trocar insertion injury has a high morbidity, mortality, and cost. The purpose of this study was to compare standard trocar entry with our reduced-force closed trocar entry technique by measuring trocar insertion force using a mechanical force gauge. METHODS In the operating room, the force gauge was inserted into a sterile glove and connected to the proximal portion of the trocar to measure insertion force. Through one incision, we used a standard closed trocar entry, while through the other incision, we used our reduced-force closed trocar entry technique. After making the skin incision and before trocar entry, we spread and dilated the skin, subcutaneous tissue, fascia, and muscle with a hemostat. RESULTS Twenty-five patients entered the trial and none were excluded. Median trocar insertion force was 3.3lb (range, 1.6 to 5.4) with our reduced-force trocar entry technique versus 6.5lb (range, 2.0 to 14.0) with the standard trocar entry (P=.001). No complications occurred with the reduced-force trocar entry technique. CONCLUSION Our reduced-force trocar entry technique decreases trocar insertion force by 50%, requires no additional instruments or cost and is fast and safe. Reduced-entry force pressure may decrease the risk of trocar insertion injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Ultrasonic Trocar Provides an Easy, Sharp, Bloodless, and Repeatable Approach to the Abdominal Cavity

Reusable trocars have the advantage of being more cost-effective than disposable trocars. However, the reusable trocar does lose its sharpness on insertion with repetitive insertion. Nonreusable trocars are expensive, but the sharpness of the knife facilitates insertion. Nonreusable trocars have a safety shield system designed to decrease abdominal organ injury, though the potential problem of ...

متن کامل

No. 193-Laparoscopic Entry: A Review of Techniques, Technologies, and Complications.

OBJECTIVE To provide clinical direction, based on the best evidence available, on laparoscopic entry techniques and technologies and their associated complications. OPTIONS The laparoscopic entry techniques and technologies reviewed in formulating this guideline include the classic pneumoperitoneum (Veress/trocar), the open (Hasson), the direct trocar insertion, the use of disposable shielded...

متن کامل

High-Pressure Trocar Insertion Technique

BACKGROUND The majority of laparoscopic complications occur at the time of Veress needle and trocar insertion. Although not very frequent, they increase the morbidity and mortality of both diagnostic and operative laparoscopic procedures. Alternative techniques of trocar insertion have been described but have not completely eliminated the risk of injury. TECHNIQUE After Veress needle insertio...

متن کامل

The Direct Trocar Technique: An Alternative Approach to Abdominal Entry for Laparoscopy

OBJECTIVE The direct trocar technique is an alternative to Veress needle insertion and open laparoscopy for accessing the abdominal cavity for operative laparoscopy. We review our approach to abdominal entry in 1385 laparoscopies performed between September 1993 and June 2000 by our group at Stanford University Hospital, a tertiary Medical Center. METHODS We performed a retrospective chart re...

متن کامل

Cell Deformation Modeling Under External Force Using Artificial Neural Network

Embryogenesis, regeneration and cell differentiation in microbiological entities are influenced by mechanical forces. Therefore, development of mechanical properties of these materials is important. Neural network technique is a useful method which can be used to obtain cell deformation by the means of force-geometric deformation data or vice versa. Prior to insertion in the needle injection pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2011