Design of a Flexural Transmission for a Dexterous Telesurgical Robot for Throat and Upper Airway: A Preliminary Result
نویسندگان
چکیده
INTRODUCTION It has been percieved by the community that one of the future significant challenges for designing surgical robots is the enhancement of robot’s mobility subject to the confined environments. Recently, Simaan, Taylor et al. [1-5] have developed a telesurgical robot for this kind of concerns. Their purpose is to design a highdexterious surgical robot which can effectively work in a confined environment such as the throat and upper airway. The aforementioned robotic system uses the masterand-slave concept as its structure. It basically consists of a da Vinci master, a stereoscopic capture and display subsystem, and a dual-arm robotic slave [5]. The master console is maneuvered by the surgeon to control the slave robotic arms, and the two slaves are supposed working together in a narrow space, like the throat and airway, to carry out the surgical operation cooperatively. Subject to the confined environment, the workspace of the slave robotic arms is limited by a long, narrow and irregularly shaped throat which can be described by a 50mm long cylinder with 40mm in diameter located 180-250mm axially down the throat [5]. Limited by the long and narrow channel, the slave arms are expected to do dexterous surgical operation such as suturing and tying knot via its end-efffectors which are located in the confined working space. Based on the design requirements and specifications as described above, the slave robotic arm has been sodesigned with a lengthy structure, Fig. 1(a). Basically, it is composed of a gross actuation unit, a hollow transmission tube and a distal dexterious unit (DDU) at which the surgical operation will be performed. The hollow transmission tube attachs the actuation unit and the DDU at its both ends, and it houses four superelastic wires for delivering the motor motion from the actuation unit to the DDU. The DDU adopts a multi-backbone snake-like robot [1] as shown in Fig. 1(b), from which the pitch-and-roll motion of the moving platform is controlled by the three outer wires (Element 3) and the grasping of the gripper is controlled by the central wire (Element 4). The whole robotic arm is engaged with a screw mechanism called the “z-θ stage” which is attached to the frame and is used to provide the yaw motion and the top-and-down motion for the DDU. Actuation unit (controlling the 3 DOFs of the DDU, i.e., pitch‐and‐roll motion and grasping)
منابع مشابه
High Dexterity Snake-Like Robotic Slaves for Minimally Invasive Telesurgery of the Upper Airway
This paper reports our efforts to develop an integrated system for telesurgery of the throat and upper airway. The system is described while focusing on the novel design of its slave robot. The slave robot is a 3-armed robot that implements novel Distal Dexterity Units (DDU’s). These DDU’s are dexterous robots for surgical tool manipulation and suturing in confined spaces. Each DDU is composed ...
متن کاملمقایسه اثر استفاده از ماسک حنجره (Laryngeal mask airway) و لوله کافدار حلقی (Cuffed pharyngeal tube) در بروز گلودرد پس از بیهوشی عمومی در بزرگسالان
Post-operative sore throat is one of the most common complications and complaints of patients after general anesthesia especially in operations that need endotracheal intubations. Its causes are: size of endotracheal tube and type of its cuff, inadequate airway humidification, trauma during intubation and suctioning, high flow of inspiratory gases, surgical manipulation of airway and adjacent o...
متن کاملCorrelation Between Upper Airways Obstructive Indexes in Adenotonsilar Hypertrophy with Mean Pulmonary Arterial Pressure
Introduction: Hypertrophied tonsils and adenoids may cause upper airway obstruction and cardio-pulmonary complications due to pulmonary arterial hypertension. The aim of this study was to determine the correlation between mean pulmonary arterial pressure (mPAP) and selected adenotonsilar hypertrophy indexes. Materials and Methods: Thirty two patients with upper-airway obstruction resulting ...
متن کاملTask-space Control of Electrically Driven Robots
Actuators of robot operate in the joint-space while the end-effect or of robot is controlled in the task-space. Therefore, designing a control system for a robotic system in the task-space requires the jacobian matrix information for transforming joint-space to task-space, which suffers from uncertainties. This paper deals with the robust task-space control of electrically driven robot manipula...
متن کاملDesign and Integration of a Telerobotic System for Minimally Invasive Surgery of the Throat
This paper presents the clinical motivation, design specifications, kinematics, statics, and actuation compensation for a newly constructed telerobotic system for Minimally Invasive Surgery (MIS) of the throat. A hybrid dual-arm telesurgical slave, with twenty joint-space Degrees of Freedom (DoF), is used in this telerobotic system to provide the necessary dexterity in deep surgical fields such...
متن کامل