Sutureless aortic valve bioprothesis '3F/ATS Enable'--4.5 years of a single-centre experience.

نویسندگان

  • Jerzy Sadowski
  • Bogusław Kapelak
  • Roman Pfitzner
  • Krzysztof Bartuś
چکیده

BACKGROUND Management of patients with acquired heart malformations, including aortic valve disease, is still challenging. Due to ageing of population, patients undergoing valve surgery are older than in the past. The 3F Therapeutics, conducting a programme of construction of heart valves for transarterial or transapical implatation, prepared the 'Enable' bioprosthetic valve for sutureless insertion in the aortic position. The first world implantation was performed in our Department on 13 January 2005. AIM To present our experience, qualification criteria and methods of implantation of sutureless bioprosthesis of aortic valve 'Enable'. METHODS The 'Enable' valve is a tubular structure, tailored and sutured of equine pericardium, treated with glutaraldehyde, and mounted on an openwork Nitinol" alloy stent. It consists of two distal rings connected with three vertical sticks. The characteristic property of nitinol is thermoplaticity: due to refrigeration it becomes elastic and easy to bend, after rewarming returns to the initial dimensions and shape, remaining stable at the body temperature. Distension of the nitinol ring make possible strong mounting of the valve in aortic annulus. The examined group consised of 27 patients (16 males, 11 females), aged 60-78 years (average 69.5), with advanced aortic valve disease, left ventricular hypertrophy, and aortic gradient up to 102 mmHg. Exclusion criteria were: severe annular deformations or bicuspid aortic valve, other valves' malformations, coronary disease, severe other comorbidities or no agreement for 'Enable' valve implantation. The patients were operated using extracorporeal circulation, general moderate hypothermia and cold crystalloid cardioplegia. Care was taken to remove calcifications, estimate of aortic annulus geometry, valve size selection, and orientation of the valve toward coronary ostia The mounting time was approximately one min, and the aorta cross-clamp time was reduced to 26-56 min, mean 30 min. RESULTS There was no mortality in the perioperative period, and during 3 months to 4.5 years of follow-up. No severe complications were present after surgery. One patient needed reoperation on post operative day 4 due to severe perivalvular leak. One other patient presented discrete leak with no need for intervention. The clinical improvement of one to three NYHA classes was observed. Echocardiographic and MSCT examinations confirmed adequate position of the valves, no structural deteriorations, normal movement and coaptation of the leaflets. The average maximal transvalvular gradient was 11.6 mmHg and the mean gradient--6.8 mmHg, which remained stable during the follow-up period. No thromboembolic or infective complications were present. CONCLUSIONS (1) The 'Enable' aortic bioprosthetic valve has very good hemodynamic properties. (2) Self-expanding thermoplastic nitinol-made ring allows permanent stable mounting. (3) The quick fixation (about 1 min) significantly shortens the operation time. (4) The 'Enable' valve seems to be suitable for patients with increased periopertive risk.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical experience with the ATS 3f Enable® Sutureless Bioprosthesis.

OBJECTIVE The ATS 3f Enable® Bioprosthesis is a self-expanding valve with a tubular design that allows for decreased leaflet stress and preservation of aortic sinuses. We report the midterm results of a prospective, multicenter clinical study evaluating the safety and efficacy of this stented bioprosthesis in patients undergoing isolated aortic valve replacement with or without concomitant proc...

متن کامل

Delayed dislocation of a sutureless aortic bioprosthesis: the first case.

Sutureless aortic bioprosthesis implantation is an alternative technique in high-risk patients undergoing aortic valve replacement with a possible reduction in the extracorporeal circuit time and reliable haemodynamic features. A 3F Enable (ATS Medical-Medtronic, Inc., Minneapolis, MN, USA) has shown very good results. We report the first upward displacement of 3F Enable three months post impla...

متن کامل

A Tricky Percutaneous Paravalvular Leak Closure Two Years After Implantation of 3f Enable Sutureless Bioprosthetic Aortic Valve.

Sutureless valves were designed in an attempt to simplify the aortic valve replacement procedure and reduce extracorporeal circuit time, whilst allowing complete excision of the calcified native valve using a minimally invasive approach. Elderly patients with significant comorbidities are considered to benefit the most, although randomized data are lacking. In registries of patients treated wit...

متن کامل

Recent developments for surgical aortic valve replacement: The concept of sutureless valve technology

Aortic stenosis has become the most frequent type of valvular heart disease in Europe and North America and presents in the large majority of patients as calcified aortic stenosis in adults of advanced age. Surgical aortic valve replacement has been recognized to be the definitive therapy which improves considerably survival for severe aortic stenosis since more than 40 years. In the most recen...

متن کامل

Minimally invasive aortic valve replacement using the Perceval S sutureless valve.

The term “sutureless aortic valve” (su-AV) describes a type of valve which facilitates anchoring of bioprostheses in the aortic position without use of conventional sutures. Although all valve prostheses used for transcatheter aortic valve implantation or replacement (TAVI or TAVR) follow the same principle, they are implanted by wire-based techniques as opposed to su-AVs, which are implanted b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kardiologia polska

دوره 67 8A  شماره 

صفحات  -

تاریخ انتشار 2009