Comparison of Etymotic insert and TDH supra-aural earphones in auditory brainstem response measurement.
نویسندگان
چکیده
There are few systematic comparisons of Etymotic ER-3A insert earphones versus supra-aural earphones in auditory brainstem response (ABR) measurement. We compared ER-3A insert earphones and two types of supra-aural earphones (TDH-39P and TDH-49P) in a group of normal hearing adults. Acoustic analyses revealed spectral and temporal differences among earphones. Behavioral and ABR thresholds to click stimuli were slightly elevated with the ER-3A compared to the TDH earphones. The ER-3A earphones produced a latency delay, relative to the TDH earphones, that varied from about 0.8 to 1.0 msec, and increased at lower stimulus intensity levels. In addition, ABR wave I amplitude was significantly reduced with the ER-3A earphone. Based on these data, we recommend collection of normative data with the ER-3A earphones prior to their use in ABR measurement.
منابع مشابه
Influence of the type of transducer in profound hearing loss.
BACKGROUND individuals with profound hearing loss may present vibrotactile responses when tested with supra-aural earphones due to the large skull area exposed to vibration in these transducers. AIM to verify the influence of the type of transducer when assessing air conducted pure tone thresholds in individuals with profound sensorineural hearing loss. METHOD 50 individuals, ranging in age...
متن کاملInsert earphones for speech recognition testing.
Performance-intensity functions for PB word lists were run on 19 normal-hearing subjects and 15 subjects with sensorineural hearing losses. Comparisons were made between standard supra-aural earphones (TDH-49P) and insert phones (ER-3A). Results showed that, at least for the higher sensation levels where word recognition tests are usually performed, the phones may be used interchangeably. Using...
متن کاملNBS-9A coupler-to-eardrum transformation: TDH-39 and TDH-49 earphones.
A transformation was derived to convert sound-pressure levels referenced to an NBS-9A coupler to corresponding eardrum sound-pressure levels. It was found that the same transformation may be used for male and female adults and for both TDH-39 and TDH-49 earphones in MX-41/AR supra-aural cushions. It was determined that from 250-2000 Hz the transformation provides an eardrum sound-pressure level...
متن کاملIndices of frequency and temporal resolution as a function of level.
Several investigators have suggested that between-subject variations in hearing aid benefit may be related to between-subject variations in auditory resolution. Evaluation of this relationship is complicated by the need to assess resolution at several frequencies and levels in hearing-impaired listeners who may not tolerate lengthy test procedures. This paper reports data from normal-hearing li...
متن کاملAcoustic mechanisms that determine the ear-canal sound pressures generated by earphones.
In clinical measurements of hearing sensitivity, a given earphone is assumed to produce essentially the same sound-pressure level in all ears. However, recent measurements [Voss et al., Ear and Hearing (in press)] show that with some middle-ear pathologies, ear-canal sound pressures can deviate by as much as 35 dB from the normal-ear value; the deviations depend on the earphone, the middle-ear ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Academy of Audiology
دوره 3 5 شماره
صفحات -
تاریخ انتشار 1992