Cryoballoon ablation for paroxysmal atrial fibrillation in the presence of an Amplatzer Septal Occluder device

نویسندگان

  • Jubran A. Rind
  • John L. Byl
  • Bennett P. Samuel
  • Joseph J. Vettukattil
  • Nagib T. Chalfoun
چکیده

Cryoballoon ablation of the pulmonary veins (CAPV) has been demonstrated to be non-inferior to radiofrequency (RF) ablation for paroxysmal atrial fibrillation (AFib). As CAPV requires a larger transseptal sheath than RF ablation, it can be challenging in the presence of an AmplatzerTM Septal Occluder (ASO) device. Real-time three-dimensional transesophageal echocardiography (RT3DTEE) provides enhanced visualization of various complex cardiac defects and has revolutionized interventional procedures by guiding catheter positioning. We describe successful RT3DTEE guided transseptal puncture for CAPV of paroxysmal AFib in the presence of an ASO in a 53-year-old male. Copyright © 2016, Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pacemaker lead entrapment complicating transcatheter closure of a patent foramen ovale.

T ranscatheter cardiovascular interventions are nowadays more frequently and safely performed, thus leading to populate the heart with medical devices. Here, we describe an unusual complication following percutaneous closure of a patent foramen ovale (PFO) with an atrial septal occluder. A 52-year-old woman with history of transient ischemic attack was found to have a PFO associated with an atr...

متن کامل

Assessment of the geometric profile of the Amplatzer and Cardioseal septal occluders by three dimensional echocardiography.

OBJECTIVE To apply three dimensional echocardiography to describe the geometric profile of the Amplatzer and Cardioseal occluders after deployment for closure of atrial septal defect. METHODS 20 patients (mean (SD) age, 14 (5) years) were enrolled for transcatheter closure of a secundum atrial septal defect with the Amplatzer occluder (10) or with the Cardioseal occluder (10). The two populat...

متن کامل

Transcatheter Repair of Iatrogenic Aortic Perforation Complicating Transseptal Puncture for a Catheter Ablation of Atrial Arrhythmia.

UNLABELLED Aortic root perforation is a potentially life-threatening complication that may occur during transseptal puncture and requires immediate repair. We present a 71-year-old man who was admitted for catheter ablation of persistent atypical atrial flutter. Fluoroscopic-guided transseptal puncture was performed to gain access to the left atrium. An unrecognized puncture of the aortic root ...

متن کامل

Urgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series

Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...

متن کامل

Nonfluoroscopic Ablation of Atrial Fibrillation Using Cryoballoon.

BACKGROUND The conventional method of cryoballoon ablation of atrial fibrillation involves the use of fluoroscopy for visual guidance. The use of fluoroscopy is accompanied by significant radiation risks to the patient and the medical staff. Herein, we report our experience in performing successful nonfluoroscopic pulmonary vein isolation using cryoballoon ablation in 5 consecutive patients wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016