High fluences inside cavity ring-down spectroscopy optical resonators lend themselves to fluorescence or Raman spectroscopy. An instrument at 488 nm was developed to measure extinction, and fluorescence of aerosols. A detection limit of 6 x 10;-9 cm;-1Hz;-1/2 (0.6 Mm;-1Hz;-1/2) was achieved. The fluorescence spectral power collected from a single fluorescent microsphere was 10 to 20 pW/nm. This power is sufficient to obtain the spectrum of a single microsphere with a resolution of 10 nm and signal-to-noise ratio of ~10. The relative concentrations of two types of fluorescent microspheres were determined from a time-integrated fluorescence measurement of a mixture of both.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser Spectroscopy for Atmospheric and Environmental Sensing

Lasers and laser spectroscopic techniques have been extensively used in several applications since their advent, and the subject has been reviewed extensively in the last several decades. This review is focused on three areas of laser spectroscopic applications in atmospheric and environmental sensing; namely laser-induced fluorescence (LIF), cavity ring-down spectroscopy (CRDS), and photolumin...

متن کامل

Optical properties of absorbing and non-absorbing aerosols retrieved by cavity ring down (CRD) spectroscopy

Application of cavity ring down (CRD) spectrometry for measuring the optical properties of pure and mixed laboratory-generated aerosols is presented. The extinction coefficient (α ext), extinction cross section (σ ext) and extinction efficiency (Q ext) were measured for polystyrene spheres (PSS), ammonium sulphate ((NH 4) 2 (SO 4)), sodium 5 chloride (NaCl), glutaric acid (GA), and Rhodamine-59...

متن کامل

Derivation of new equations for phase-shift cavity ring-down spectroscopy.

Current phase-shift cavity ring-down spectroscopy (PS-CRDS) experiments make use of equations originally developed for fluorescence studies. As these equations fail to take the length of the optical cavity and the superposition of reflecting beams into account, they lose validity as the length of the cavity increases. A new set of equations, based solely on the principles of PS-CRDS, is develop...

متن کامل

Optical heterodyne detection in cavity ring-down spectroscopy

Polarization-selective optical heterodyne detection is shown to enhance the practical sensitivity of cavity ring-down spectroscopy. Initial experiments demonstrate a signal-to-noise ratio above 31 dB. Minor improvements should yield shot-noise-limited operation. q 1998. Published by Elsevier Science B.V. All rights reserved.

متن کامل

Single-cell detection by cavity ring-down spectroscopy

The implementation of cavity ring-down spectroscopy in an optical fiber resonator extends the viability of this highly sensitive technique for label-free detection of biological species. By chemically treating the surface of discrete tapered sensing regions along the length of a physically extended optical fiber resonator, we show single-cell sensitivity arising from optical scattering of the e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 13 9  شماره 

صفحات  -

تاریخ انتشار 2005