Optimization of a novel large field of view distortion phantom for MR‐only treatment planning

نویسندگان

  • Ryan G. Price
  • Robert A. Knight
  • Ken‐Pin Hwang
  • Ersin Bayram
  • Siamak P. Nejad‐Davarani
  • Carri K. Glide‐Hurst
چکیده

PURPOSE MR-only treatment planning requires images of high geometric fidelity, particularly for large fields of view (FOV). However, the availability of large FOV distortion phantoms with analysis software is currently limited. This work sought to optimize a modular distortion phantom to accommodate multiple bore configurations and implement distortion characterization in a widely implementable solution. METHOD AND MATERIALS To determine candidate materials, 1.0 T MR and CT images were acquired of twelve urethane foam samples of various densities and strengths. Samples were precision-machined to accommodate 6 mm diameter paintballs used as landmarks. Final material candidates were selected by balancing strength, machinability, weight, and cost. Bore sizes and minimum aperture width resulting from couch position were tabulated from the literature (14 systems, 5 vendors). Bore geometry and couch position were simulated using MATLAB to generate machine-specific models to optimize the phantom build. Previously developed software for distortion characterization was modified for several magnet geometries (1.0 T, 1.5 T, 3.0 T), compared against previously published 1.0 T results, and integrated into the 3D Slicer application platform. RESULTS All foam samples provided sufficient MR image contrast with paintball landmarks. Urethane foam (compressive strength ∼1000 psi, density ~20 lb/ft3 ) was selected for its accurate machinability and weight characteristics. For smaller bores, a phantom version with the following parameters was used: 15 foam plates, 55 × 55 × 37.5 cm3 (L×W×H), 5,082 landmarks, and weight ~30 kg. To accommodate > 70 cm wide bores, an extended build used 20 plates spanning 55 × 55 × 50 cm3 with 7,497 landmarks and weight ~44 kg. Distortion characterization software was implemented as an external module into 3D Slicer's plugin framework and results agreed with the literature. CONCLUSION The design and implementation of a modular, extendable distortion phantom was optimized for several bore configurations. The phantom and analysis software will be available for multi-institutional collaborations and cross-validation trials to support MR-only planning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes

Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...

متن کامل

Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...

متن کامل

Evaluation of Magnetic Resonance Imaging for Treatment Planning for Brachytherapy for Cervical Cancer

A new phantom was designed and built in order to quantify the spatial distortions produced in images taken by MRI for treatment planning of brachytherapy for cervical cancer. It was found that for a field of view of 30 cm; large enough to incorporate the anatomy required to plan treatment, the distortions were of the order of millimetres or individual pixels. The images were compared to ones ta...

متن کامل

Assessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements

Introduction:  Image  distortion  is  one  of  the  major  problems  of  magnetic  resonance  imaging  (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is  widely known that the most obvious effect of the inhomogenity of the magnetic fields and the  nonlinearity  of  the  gradient  is  the  Geometric  Distortion  of  MR  tomograms.  In  this  study,  the...

متن کامل

Toward Magnetic Resonance Only Treatment Planning: Distortion Mitigation And Image-Guided Radiation Therapy Validation

TOWARD MAGNETIC RESONANCE ONLY TREATMENT PLANNING: DISTORTIONMITIGATION AND IMAGE-GUIDED RADIATION THERAPY VALIDATIONbyRYAN GLEN PRICEAugust 2016Advisor: Dr. Carri K. Glide-Hurst Major: Medical PhysicsDegree: Doctor of PhilosophyWhile MR-only treatment planning has shown promise, there are still severalwell-known challenges that are currently limiting widespread ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017