Minimizing contrast medium dose during transapical aortic valve implantation: it is worth the effort.

نویسندگان

  • Michael A Borger
  • David M Holzhey
  • Friedrich W Mohr
چکیده

cardiac catheterization contrast-induced acute kidney injury. Am J Cardiol 2008;102:1482–6. [23] Solomon RJ, Mehran R, Natarajan MK, Doucet S, Katholi RE, Staniloa CS et al. Contrast-induced nephropathy and long-term adverse events: cause and effect? Clin J Am Soc Nephrol 2009;4:1162–9. [24] Gupta R, Gurm HS, Bhatt DL, Chew DP, Ellis SG. Renal failure after percutaneous coronary intervention is associated with high mortality. Catheter Cardiovasc Interv 2005;64:442–8. [25] Ferrari E, Sulzer C, Rizzo E, von Segesser LK. A fully echo-guided trans-apical aortic valve implantation. Eur J Cardiothorac Surg 2009;36: 938–40.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transapical approach for transcatheter aortic valve implantation.

With the advancement of device technology and procedural techniques, most transcatheter aortic valve implantation (TAVI) procedures have been performed with the transfemoral approach in recent years (1). However, alternative approaches such as transapical, trans-subclavian, direct aortic and others still play an important role in patients with poor vascular access. Transapical approach is the o...

متن کامل

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

How we do it: effective stabilization of the apical delivery sheath during transapical aortic valve implantation.

A technique is described by which an effective stabilisation of the apical introducer sheath is achieved by a pneumatic holding arm, during transapical aortic valve implantation procedure.

متن کامل

Evolution of anaesthesia in transapical aortic valve implantation

The Transcatheter Aortic Valve Implantation (TAVI) had emerged more and more in the last twenty years. According to the scientifi c literature, this is an approved, suitable and alternative therapeutic choice to conventional surgery for aortic valve disease in high risk patients. The most of patients are octogenarians or nonagenarians, with multiple comorbidities (neurological,vascular,oncologi...

متن کامل

Severe Valvular Regurgitation: An Unexpected Complication During Transapical Aortic Valve Implantation Treated Successfully with the "Valve-in-Valve" Procedure.

Severe symptomatic aortic stenosis (AS) in a multimorbid 77 year old female was treated with transapical aortic valve implantation with a 23 mm Edwards Sapien valve. Severe valvular regurgitation following implantation, probably due to structural valve failure, was treated successfully with a second valve-in-valve implantation. During a follow-up time of 2,5 years no further problems occurred.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 41 6  شماره 

صفحات  -

تاریخ انتشار 2012