Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training

نویسندگان

  • Cristiane do Prado
  • Ruth Guinsburg
  • Maria Fernanda Branco de Almeida
  • Renata Suman Mascaretti
  • Luciana Assis Vale
  • Luciana Branco Haddad
  • Celso Moura Rebello
  • Chiara Lazzeri
چکیده

AIM To compare the influence of devices for manual ventilation and individual experience on the applied respiratory mechanics and sustained lung inflation. METHODS A total of 114 instructors and non-instructors from the Neonatal Resuscitation Program of the Brazilian Society of Pediatrics participated in this study. Participants ventilated an intubated manikin. To evaluate respiratory mechanics and sustained lung inflation parameters, a direct comparison was made between the self-inflating bag and the T-shaped resuscitator (T-piece), followed by an analysis of the effectiveness of the equipment according to the participants' education and training. RESULTS A difference between equipment types was observed for the tidal volume, with a median (interquartile range) of 28.5 mL (12.6) for the self-inflating bag and 20.1 mL (8.4) for the T-piece in the instructor group and 31.6 mL (14) for the self-inflating bag and 22.3 mL (8.8) for the T-piece in the non-instructor group. Higher inspiratory time values were observed with the T-piece in both groups of professionals, with no significant difference between them. The operator's ability to maintain the target pressure over the 10 seconds of sustained lung inflation was evaluated using the area under the pressure-time curve and was 1.7-fold higher with the use of the T-piece. Inspiratory pressure and mean airway pressure applied during sustained lung inflation were greater with the self-inflating bag, as evaluated between the beginning and the end of the procedure. CONCLUSION The T-piece resulted in lower tidal volume and higher inspiratory time values, irrespective of the operator's experience, and increased the ease of performing the sustained lung inflation maneuver, as demonstrated by the maintenance of target pressure for the desired period and a higher mean airway pressure than that obtained using the self-inflating bag.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sustained Hypoxic Pulmonary Vasoconstriction in the Isolated Perfused Rat Lung: Effect of α1-adrenergic Receptor Agonist

Background: Alveolar hypoxia induces monophasic pulmonary vasoconstriction in vivo, biphasic vasoconstriction in the isolated pulmonary artery, and controversial responses in the isolated perfused lung. Pulmonary vascular responses to sustained alveolar hypoxia have not been addressed in the isolated perfused rat lung. In this study, we investigated the effect of sustained hypoxic ventilation o...

متن کامل

Effect of Lung Manual Hyperinflation (MHI) on Oxygenation of Patients Following Abdominal Surgery and T-Tube Support

Background: Postoperative pulmonary complications (PPC) are of the major reasons for death. Prolonged mechanical ventilation (PMV) and delayed extubation are leading to the incidence of more seriously complications. The effect of hyperinflation has not been investigated in control of these complications in patients who have been weaned from mechanical ventilation and are undergoing T-tube suppo...

متن کامل

Does sustained lung inflation at resuscitation reduce lung injury in the preterm infant?

BACKGROUND Bronchopulmonary dysplasia (BPD) is a common outcome of preterm birth. Experimental animal work has shown that initial ventilation strategies injure the immature lung and may lead to BPD. Studies with asphyxiated babies have shown that, if tidal ventilation at birth is preceded by sustained lung inflation, larger inflation volumes can be achieved, which is thought to lead to clearanc...

متن کامل

Sustained inflation and incremental mean airway pressure trial during conventional and high-frequency oscillatory ventilation in a large porcine model of acute respiratory distress syndrome

BACKGROUND To compare the effect of a sustained inflation followed by an incremental mean airway pressure trial during conventional and high-frequency oscillatory ventilation on oxygenation and hemodynamics in a large porcine model of early acute respiratory distress syndrome. METHODS Severe lung injury (Ali) was induced in 18 healthy pigs (55.3 +/- 3.9 kg, mean +/- SD) by repeated saline lun...

متن کامل

Manual ventilation and risk of barotrauma: primum non nocere.

Optimizing bag ventilation during cardiopulmonary resuscitation or ventilation of an unprotected airway1 is mandatory to minimize the risk of pulmonary complications and the occurrence of gastric inflation due to excessive airway pressure.2 Numerous studies have underlined the difficulty of providing safe and effective bag ventilation in these situations, and new devices have been marketed to h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016