Time dependent accuracy of dental radiometers.

نویسندگان

  • Danijela Marović
  • Sanja Matić
  • Katarina Kelić
  • Eva Klarić
  • Mario Rakić
  • Zrinka Tarle
چکیده

Inadequate intensity of the polymerization light source can compromise the quality and longevity of dental composite restorations. In order to maintain optimal strength of polymerization devices, regular control of polymerization units is necessary. The aim of this study was to compare the accuracy of two radiometers in the measurement of light intensity of photopolymerization devices concerning the time point of measurement. Light intensity measurements of 16 halogen and 8 LED curing lights were performed using three different devices at the beginning as well as 10 and 40 seconds after the start of illumination. Two were handheld radiometers: Bluephase meter (BM) and Cure Rite (CR), while an integrating sphere (IS) represented the reference device. Data were statistically analyzed using Friedman's test and Wilcoxon signed-rank test (p < 0.05). The values at the beginning and after 10 seconds measured by BM were significantly higher than the measurements by IS, whereas CR showed higher values after 10 and 40 seconds. Both commercial radiometers tended to overestimate the light intensity of LED and halogen curing units when compared to the reference device. The time point of measurement influences the output value. The heating of radiometers was proposed as a possible explanation for the inaccuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Emitted Wavelength and Light Guide Type on Irradiance Discrepancies in Hand-Held Dental Curing Radiometers

The purpose of this study was to determine any discrepancies in the outputs of five commercial dental radiometers and also to evaluate the accuracy of these devices using a laboratory-grade spectroradiometer. The power densities of 12 different curing light sources were repeatedly measured for a total of five times using each radiometer in a random order. The emission spectra of all of the curi...

متن کامل

Vicarious Calibration Based Cross Calibration of Solar Reflective Channels of Radiometers Onboard Remote Sensing Satellite and Evaluation of Cross Calibration Accuracy through Band-to-Band Data Comparisons

Accuracy evaluation of cross calibration through band-to-band data comparison for visible and near infrared radiometers which onboard earth observation satellites is conducted. The conventional cross calibration for visible to near infrared radiometers onboard earth observation satellites is conducted through comparisons of band-to-band data of which spectral response functions are overlapped m...

متن کامل

Noise-Optimized Silicon Radiometers

This paper describes a new, experimentally verified, noise analysis and the design considerations of the dynamic characteristics of silicon radiometers. Transimpedance gain, loop gain, and voltage gain were optimized versus frequency for photodiode current meters measuring ac and dc optical radiation. Silicon radiometers with improved dynamic characteristics were built and tested. The frequency...

متن کامل

ALMA Memo No. 495 Estimated Performance of the Water Vapour Radiometers

The sensitivity and accuracy to be expected from the ALMA water vapour radiometers is estimated. Even with quite pessimistic assumptions about noise temperature and gain stability, it appears that the sensitivity of the present design is at least a factor of 2 better than the specifications. It is more difficult to predict the medium term stability and accuracy that will be achieved, but the in...

متن کامل

Comparative Study of the Effect of Storage Environment Temperature on the Accuracy of Hygedent and Chromogel Alginate Impression Materials

Background and Aim: Considering the lack of sufficient and even contradictory studies on the effect of temperature-dependent dimensional changes of alginate before pouring, this study aimed to investigate the effect of storage temperature of Hygedent and Chromogel alginate molds on dimensional stability.  Materials and Methods: In this in-vitro experimental study, dimensional changes of two t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta clinica Croatica

دوره 52 2  شماره 

صفحات  -

تاریخ انتشار 2013