Optimal optode montage on electroencephalography/functional near-infrared spectroscopy caps dedicated to study epileptic discharges.

نویسندگان

  • Alexis Machado
  • Odile Marcotte
  • Jean Marc Lina
  • Eliane Kobayashi
  • Christophe Grova
چکیده

Functional near-infrared spectroscopy (fNIRS), acquired simultaneously with electroencephalography (EEG), allows the investigation of hemodynamic brain responses to epileptic activity. Because the presumed epileptogenic focus is patient-specific, an appropriate source/detector (SD) montage has to be reconfigured for each patient. The combination of EEG and fNIRS, however, entails several constraints on montages, and finding an optimal arrangement of optodes on the cap is an important issue. We present a method for computing an optimal SD montage on an EEG/fNIRS cap that focuses on one or several specific brain regions; the montage maximizes the spatial sensitivity. We formulate this optimization problem as a linear integer programming problem. The method was evaluated on two EEG/fNIRS caps. We simulated absorbers at different locations on a head model and generated realistic optical density maps on the scalp. We found that the maps of optimal SD montages had spatial resolution properties comparable to those of regular SD arrangements for the whole head with significantly fewer sensors than regular SD arrangements. In addition, we observed that optimal montages yielded improved spatial density of fNIRS measurements over the targeted regions together with an increase in signal-to-noise ratio.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic Response to Interictal Epileptiform Discharges Addressed by Personalized EEG-fNIRS Recordings

OBJECTIVE We aimed at studying the hemodynamic response (HR) to Interictal Epileptic Discharges (IEDs) using patient-specific and prolonged simultaneous ElectroEncephaloGraphy (EEG) and functional Near InfraRed Spectroscopy (fNIRS) recordings. METHODS The epileptic generator was localized using Magnetoencephalography source imaging. fNIRS montage was tailored for each patient, using an algori...

متن کامل

fNIRS-EEG study of focal interictal epileptiform discharges.

Functional near-infrared spectroscopy (fNIRS) acquired with electroencephalography (EEG) is a relatively new non-invasive neuroimaging technique with potential for long term monitoring of the epileptic brain. Simultaneous EEG-fNIRS recording allows the spatio-temporal reconstruction of the hemodynamic response in terms of the concentration changes in oxy-hemoglobin (HbO) and deoxy-hemoglobin (H...

متن کامل

Reducing motion artifacts for long-term clinical NIRS monitoring using collodion-fixed prism-based optical fibers

As the applications of near-infrared spectroscopy (NIRS) continue to broaden and long-term clinical monitoring becomes more common, minimizing signal artifacts due to patient movement becomes more pressing. This is particularly true in applications where clinically and physiologically interesting events are intrinsically linked to patient movement, as is the case in the study of epileptic seizu...

متن کامل

Hemodynamic changes during posterior epilepsies: an EEG-fNIRS study.

Posterior epilepsies are mainly characterized clinically by visual symptoms. Functional near-infrared spectroscopy (fNIRS) is an emerging non-invasive imaging technique that has the potential to monitor hemodynamic changes during epileptic activity. Combined with electroencephalography (EEG), 9 patients with posterior epilepsies were recorded using EEG-fNIRS with large sampling (19 EEG electrod...

متن کامل

Cerebral near infrared spectroscopy: emitter-detector separation must be increased.

We have compared the effect of increasing optode separation (range 0.7-5.5 cm) on the sensitivity of near infrared spectroscopy (NIRS) to discrete reductions in scalp and cerebral oxygenation in 10 healthy men (mean age 32, range 26-39 yr) using multichannel NIRS. During cerebral oligaemia (a mean reduction in middle cerebral artery flow velocity of 47%) induced by a mean reduction in end-tidal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 19 2  شماره 

صفحات  -