Glycosylated hemoglobin measured by affinity chromatography: micro-sample collection and room-temperature storage.
نویسندگان
چکیده
Under proper conditions, whole blood can be stored at room temperature for as long as 21 days before measurement of glycosylated hemoglobin by affinity chromatography. Whole blood (anticoagulated with EDTA or heparin) was placed in capillary tubes, which were then sealed at both ends and stored at room temperature. Just before assay, whole blood was rinsed from the tubes and diluted 10-fold with water. Samples of each patient's blood were assayed as whole-blood hemolysates by affinity chromatography after zero, seven, 14, and 21 days of storage. Values for glycosylated hemoglobin did not change over 21 days of storage and values for each storage day correlated well (r = 0.97, p less than .0001) with hemoglobin A1C measured in fresh erythrocyte hemolysates by "high-performance" liquid ion-exchange chromatography.
منابع مشابه
Effects of whole blood storage on results for glycosylated hemoglobin as measured by ion-exchange chromatography, affinity chromatography, and colorimetry.
After storage of whole blood at either 4 or 20 degrees C, results for glycosylated hemoglobin by ion-exchange chromatography ("high-performance" liquid and mini-column chromatography), thiobarbituric acid colorimetry, and affinity chromatography were compared. At 4 degrees C, all methods gave acceptable results for samples stored for as long as a week. At 20 degrees C, the colorimetric and affi...
متن کاملCollection of blood on filter paper for measurement of glycated hemoglobin by affinity chromatography.
We present data on a filter-paper collection and assay method for measurement of glycated hemoglobin (gHb). Onto filter paper dipped into a solution of glucose oxidase (EC 1.1.3.4) and allowed to dry, approximately 20 microL of capillary blood was spotted. For analysis, we eluted the dried blood spot from the paper by soaking in water for 1 h, then measured the gHb in the eluate by affinity chr...
متن کاملDetermination of glycosylated hemoglobin by affinity chromatography: comparison with colorimetric and ion-exchange methods, and effects of common interferences.
An affinity-chromatographic method for determination of glycosylated hemoglobin (Anal. Lett. 14: 649-661, 1981) is compared with the thiobarbituric acid colorimetric (I) (Clin. Chem. 27: 669-672, 1981) and the ion-exchange liquid-chromatographic (II) (Diabetes 29: 623-628, 1980) methods. A correlation of 0.98 was obtained for the affinity method vs II and 0.97 for affinity vs I (n = 51). The wi...
متن کاملMeasurement of glycosylated hemoglobins using boronate affinity chromatography.
A boronate affinity column method for the measurement of glycosylated hemoglobins was evaluated. In the procedure the glycosylated hemoglobins were bound by immobilized boronic acid to separate them from nonglycosylated hemoglobins. Elution of bound glycosylated hemoglobins was carried out with sorbitol buffer, and the absorbance was read at 414 nm. The method was linear to a glycosylated hemog...
متن کاملHemoglobin variant detection from dried blood specimens by high performance liquid chromatography.
The convenience of dried blood filter paper specimens for genetic screening programs has prompted us to test the stability of these specimens for hemoglobin identification by cation exchange high performance liquid chromatography. This report shows that identification of Hb AA, Hb AF, Hb AS, Hb FAS, Hb AJ, Hb FJ, Hb EF, and Hb SS can be achieved by high performance liquid chromatography even af...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 29 6 شماره
صفحات -
تاریخ انتشار 1983