Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere.

نویسندگان

  • P M Fong
  • D C Keil
  • M D Does
  • J C Gore
چکیده

Polymer gels whose NMR and optical properties change when irradiated offer unique advantages for measuring radiation dose distributions. To date, all acrylic polymer gel dosimeters must be manufactured, stored and irradiated in hypoxic conditions which severely limits their use and stability. A new formulation of acrylic dosimeter gel has been developed that responds well in normal atmosphere and which we have named MAGIC (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper). To produce dosimeter gels, an aqueous solution of gelatin, open to the atmosphere, is mixed with methacrylic acid, copper(II) ions, ascorbic acid and hydroquinone. It is believed that the copper(II) and ascorbic acid form a complex with oxygen which (with radiolysis of water) serves as a free radical source for the initiation of the polymerization of methacrylic acid. At room air the water proton spin relaxation rate R2 in MAGIC gels is proportional to absorbed dose though the precise relationship depends on the composition of the gel and the initiating complex. For example, in the range 0-30 Gy the slope of the response of R2 versus dose at 20 MHz was 0.300, 0.519 and 0.681 s(-1) Gy(-1), respectively, when the concentration of MAA was 3, 6 and 9%. The slopes increased to 0.310, 0.567 and 0.868 s(-1) Gy(-1) at 85 MHz. An important determinant of the sensitivity to detect small dose changes is shown to be the slope-to-intercept ratio of the dose-response curve. These varied from 0.08 to 0.17, comparable to hypoxic gels described earlier. MAGIC gels can be manufactured and used much more easily than the previous formulations and can be imaged by magnetic resonance imaging or optical scanning, and thus they will likely be of considerable interest to radiation physicists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

متن کامل

Uncertainty Analysis in MRI-based Polymer Gel Dosimetry

Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...

متن کامل

Magnetic-Resonance-Imaging based Polymer Gel Dosimetry: Methodology, Spatial Resolution, Applications

Modern radiation techniques aim on improved 3-dimensional (3D) spatial selectivity of the dose application sparing dose from organs-at-risk (e.g. IMRT with micro-multileaf collimation, γ-knife-, Brachyand heavy-ion therapy). The corresponding 3D-dose distributions exhibit high dose gradients above 4 Gy/mm, which are difficult to be investigated using standard single-point dosimetric detectors ...

متن کامل

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...

متن کامل

The Ability of Ultrasonic Characterization to Extract the Dose Distribution of MAGIC-f Polymer Gel

Background & Aims: Today, different imaging techniques have been studied in the reading of radiationsensitive polymer gels dosage. Due to limitations of imaging techniques such as magnetic resonance imaging (MRI) and computed tomography (CT), ultrasound techniques are proposed for dose-dependent parameter extraction. In this study, using MAGIC-f (methacrylic and ascorbic acid in gelatin initiat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 46 12  شماره 

صفحات  -

تاریخ انتشار 2001