Fetal transabdominal pulse oximeter studies using a hypoxic sheep model.
نویسندگان
چکیده
OBJECTIVE This study investigates the validity of transabdominal pulse oximetry using a sheep fetal hypoxia model with fetal arterial hemoglobin saturation. METHODS Four pregnant ewes were anaesthetized and cannulated through the brachial artery to measure direct arterial blood saturation, SaO(2). Next, the transabdominal pulse oximeter was used to measure indirect measurement of the arterial saturation of the fetus, SpO(2), from the maternal abdomen. Hypoxia was induced by a balloon placed in the maternal aorta. RESULTS There is a linear relationship between SaO(2), arterial blood saturation values of the fetus, and SpO(2), the values measured by the transabdominal pulse oximetry with a slope of 0.75 (r(2)=0.76). CONCLUSION This information can be used to calibrate the transabdominal pulse oximeter as a measurement of fetal arterial saturation. With these results, we can advance the accurate, no-risk, noninvasive transabdominal fetal pulse oximeter for human use. This research may contribute to the more accurate diagnosis of the diseases of the fetus including Hypoxic Ischemic Encephalopathy.
منابع مشابه
Transabdominal near infrared oximetry of hypoxic stress in fetal sheep brain in utero.
The feasibility of transabdominal near-infrared (NIR) spectroscopy for detecting and quantifying fetal hypoxia in utero is demonstrated in a pregnant ewe model. A frequency domain NIR spectroscopy probe, consisting of two detectors and six sources operating at three wavelengths (675, 786, and 830 nm), was placed on the maternal abdomen directly above the fetal head. Fetal hypoxia was indirectly...
متن کاملNail polish does not significantly affect pulse oximetry measurements in mildly hypoxic subjects.
BACKGROUND The effect of nail polish on pulse oximetry measurements in non-hypoxic subjects has been studied extensively. Some studies found that nail polish decreased pulse-oximetry (S(pO(2))) values, whereas others found no effects from nail polish. OBJECTIVE To determine if nail polish affects S(pO(2)) measurements in mildly hypoxic subjects. METHODS At high altitude, 5 investigators, wh...
متن کاملAdapting new bedside instrumentation for computer-aided fetal monitoring using efficient tools for system reconfiguration
Incorporating of the new pulse oximetry feature into computer-aided fetal monitoring system requires a lot of modifications in hardware and software structure of the system. Since these modifications are fairly time-consuming, such a solution would be impracticable during preliminary testing and evaluation phases of new medical instrument. Therefore, at first we decided to build a prototype sys...
متن کاملNotes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry.
Multi-wavelength photometers, blood gas analysers and pulse oximeters are widely used to measure various oxygen-related quantities. The definitions of these quantities are not always correct. This paper gives insight in the various definitions for oxygen quantities. Furthermore, the possible influences of dyshaemoglobins and fetal haemoglobin on the accuracy of pulse oximetry are discussed. As ...
متن کاملPulseless Pulse Oximetry.
We read with great interest the article by Aldrich et al 1 in this issue of CHEST (see page 1484 ). In 2003, we reported our trial of measuring noninvasive arterial saturation during a pulseless situation (cardiopulmonary bypass [CPB]) by inducing a simulated pulse. 2 We were interested in fi nding a way to obtain pulse oximeter function during CPB at the time because we had experienced a morta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians
دوره 17 6 شماره
صفحات -
تاریخ انتشار 2005