Rapid 3D Parallel Imaging of Non-Cartesian Data
نویسنده
چکیده
Introduction: The 3D Pretty Easy Parallel Imaging (PEPI) technique, previously presented as a 2D technique [1], is a coil sensitivity based method used for reconstructing arbitrary 3D k-space trajectories. PEPI is an iterative technique that enforces receive b1-field and sampled data consistency in each iteration (eg. [2-4]). The 3D trajectory used is Spiral Projection Imaging (SPI) [3]. Methods: SPI: The trajectory described in figure 1 consists of fully sampled spiral planes rotated about the kz axis. Undersampling in kx-ky is caused by omitting planes from the fully sampled sphere in figure 1(b,c). Scan Parameters are: FOV 24cm, 1mm Res., 384 planes (fully sampled), 75 spiral arms, TE/TR = 0.6/9.9ms, scan time 5min (fully sampled), GE 3T Signa Excite System, 8-channel head coil. Subsampling the full set by factors of 4, 8, and 12 required 96, 48, 32 planes respectively. PEPI: Figure 2 shows the iteration loop. Coil combination in image space pushes data out from the SPI trajectory into non-sampled k-space. The new data are kept by masking the skipped k-space locations and recombining with original data in the next iteration. This is performed without the need for degridding and gridding operations at each iteration, improving computation speed. Results: Figure 3 shows a comparison between fully sampled gridded k-space, undersampled gridded k-space, and PEPI reconstructed data. Total reconstruction time for undersampling by 4 is 56min. The number of PEPI iterations is 18 and takes 10min. Reconstruction was performed on an 8-CPU 3GHz Intel Xeon machine. Conclusion: PEPI improves image quality at each level of undersampling used with arbitrary 3D SPI trajectories. PEPI provides rapid reconstruction times with less than 20% of the total reconstruction taken by the iteration process. References: [1] Pipe, ISMRM 2009, abstract 2722; [2] Pruessmann et al., MRM, 46:638, 2001; [3] Lustig et al., ISMRM 2007, abstract 333; [4] Wajer et al., ISMRM 2001, abstract 767; [5] Irarrazabal, P., MRM, 33:656, 1995
منابع مشابه
Three-dimensionally accelerated radial parallel MRI with a 32-channel coil system
Introduction: Established parallel-imaging techniques include the one-dimensional or two-dimensional acceleration of data acquisition with Cartesian or non-Cartesian trajectories [1–4]. However, state-of-the-art receiver coil arrays with 32 and more coil elements that are distributed approximately uniformly in space should also enable a three-dimensional (3D) parallel-imaging acceleration, i.e....
متن کاملThrough-time 3D radial GRAPPA for whole heart cardiac imaging
Background Through-Time Non-Cartesian GRAPPA has been previously demonstrated for real-time 2D cardiac imaging (Seiberlich, et al. Magn Reson Med. 2011 Feb;65(2):492505.). This parallel imaging method works by acquiring several fully-sampled non-Cartesian datasets with a low temporal resolution, and using the coil sensitivity information from these datasets to reconstruct highly undersampled no...
متن کاملAugmented Lagrangian with Variable Splitting for Faster Non-Cartesian 𝕃1-SPIRiT MR Image Reconstruction
SPIRiT (iterative self-consistent parallel imaging reconstruction), and its sparsity-regularized variant L1-SPIRiT, are compatible with both Cartesian and non-Cartesian magnetic resonance imaging sampling trajectories. However, the non-Cartesian framework is more expensive computationally, involving a nonuniform Fourier transform with a nontrivial Gram matrix. We propose a novel implementation ...
متن کاملRapid non-Cartesian Parallel Imaging Reconstruction on Commodity Graphics Hardware
Introduction In this abstract we advocate the concept of real-time non-Cartesian magnetic resonance imaging with minimal reconstruction delay. We focus on cardiac imaging although the presented techniques are generally applicable. Parallel imaging techniques such as SENSE [1] and k-t SENSE [2] have been available for years for realtime acquisition. Until now however, available reconstruction im...
متن کاملFree-breathing liver perfusion imaging using 3-dimensional through-time spiral generalized autocalibrating partially parallel acquisition acceleration.
OBJECTIVES The goal of this study was to develop free-breathing high-spatiotemporal resolution dynamic contrast-enhanced liver magnetic resonance imaging using non-Cartesian parallel imaging acceleration, and quantitative liver perfusion mapping. MATERIALS AND METHODS This study was approved by the local institutional review board and written informed consent was obtained from all participant...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009