Rapid and Accurate Ic50 Determination Using Logarithmic Concentration Generator
نویسندگان
چکیده
This paper proposes an effective methodology for the determination of the half maximal (50%) inhibitory concentration (IC50) by using microfluidic device that generates logarithmic concentration gradients. Dose-response curve is obtained with respect to the concentrations in a logarithmic scale. Although we have presented a high-throughput analysis of ATP binding cassette transporter (ABC-transporter) by using linear concentration generator [1] and fluorescent substrates [2], logarithmic concentration generator is demanded for rapid and accurate IC50 determination as shown in Fig. 1. We designed a microfluidic device composed of branching micro-channels where samples are divided and mixed to generate designated concentrations. Finally inhibition analysis of substrate transport was conducted by linear and logarithmic concentration generators. We found that logarithmic concentration generators are useful for the accurate determination of IC50 by a fewer number of tests than linear concentration generators.
منابع مشابه
Nonlinear concentration gradients regulated by the width of channels for observation of half maximal inhibitory concentration (IC50) of transporter proteins.
This paper describes a simple microfluidic device that can generate nonlinear concentration gradients. We changed the "width" of channels that can drastically shorten the total microfluidic channel length and simplify the microfluidic network design rather than the "length" of channels. The logarithmic concentration gradients generated by the device were in good agreement with those obtained by...
متن کاملDetermination of 5-Hydroxymethyl-2-furaldehyde of Crude and Processed Fructus Corni in Freely Moving Rats Using In Vivo Microdialysis Sampling and Liquid Chromatography
The purpose of this study was to develop a sensitive and fast microdialysis coupled with high-performance liquid chromatographic (HPLC) method for determination of 5-hydroxymethyl-2-furaldehyde (5-HMF) in free-moving rats after i.g. administration of the aqueous extract of crud Fructus corni and its processed products of jiuzheng pin (JZP). The concentration of 5-HMF in free-movi...
متن کاملRapid Determination of Chromium (M)lli Natural Water and Industrial Effluents Using Kinetic Speetrophotometric Method
A new simple arid rapid catalytic kinetic method for determination of trace amounts of chromium (110 isdescribed. The method is based on the catalytic effect of chromium (III) on the reduction of Methylene blue byascorbic acid in acidic media. The reaction monitored smectrophotomenically by measuring the decrease ofabsorbance at 664 nm at 25 C. The fixed-time method was used for the first 300 s...
متن کاملTime-Resolved Cell Culture Assay Analyser (TReCCA Analyser) for the Analysis of On-Line Data: Data Integration—Sensor Correction—Time-Resolved IC50 Determination
Time-resolved cell culture assays circumvent the need to set arbitrary end-points and reveal the dynamics of quality controlled experiments. However, they lead to the generation of large data sets, which can represent a complexity barrier to their use. We therefore developed the Time-Resolved Cell Culture Assay (TReCCA) Analyser program to perform standard cell assay analyses efficiently and ma...
متن کاملDetermining the Lethal Concentration of Formalin to Koi fish (Cyprinus carpio)
Formalin is a chemical disinfectant for surface and premises beside its effect on several infective pathogens in ornamental and food fishes. Determination of formalin concentration for precious fish is critical. This problem is so important because of the aquarium fish varieties. In this study, OECD standard method was used for Koi fish formalin LC50 assessment. After a series of basic experime...
متن کامل