Development of a rapid point-of-care patient reported outcome measure for cataract surgery in India

نویسندگان

  • Joshua R. Ehrlich
  • Charlie Frank
  • Josiah Smiley
  • Hong-Gam Le
  • Sanil Joseph
  • Stephen G. Schilling
  • Brian C. Stagg
  • Joshua D. Stein
  • R. D. Ravindran
  • Aravind Haripriya
چکیده

BACKGROUND For patient undergoing cataract surgery in India, existing patient-reported outcome (PRO) measures are either not culturally relevant, have not been adequately validated, or are too long to be used in a busy clinical setting. We sought to develop and validate a brief and culturally relevant point-of-care PRO measure to address this need. METHODS Twelve items from the Indian Visual Functioning Questionnaire (IND-VFQ) were selected based on preliminary data. Patients 18 years and older were prospectively recruited at Aravind Eye Care System in Madurai, India. Clinical and sociodemographic data were collected and the 12-item short-form IND-VFQ (SF-IND-VFQ) was administered pre- and post-operatively to 225 patients; Factor analysis and Rasch modeling was performed to assess its psychometric properties. RESULTS One item that did not fit a unidimensional scale and had poor fit with the Rasch model was eliminated from the questionnaire. The remaining 11 items represented a single construct (no residual correlations> 0.1) and were largely unaffected by differential item functioning. Five items had disordered thresholds resolved by collapsing the response scale from four to three categories. The survey had adequate reliability (0.80) and good construct (infit range, 0.77-1.29; outfit range, 0.56-1.30) and content (item separation index, 5.87 logits) validity. Measurement precision was fair (person separation index, 1.97). There was evidence that items were not optimally targeted to patients' visual ability (preoperatively, - 1.92 logits; overall, - 3.41 logits), though the survey measured a very large effect (Cohen's d 1.80). In a subset of patients, the average time to complete the questionnaire was 2 min 6.3 s. CONCLUSIONS The SF-IND-VFQ is a valid, reliable, sensitive, and rapidly administered point-of-care PRO measure to assess changes in visual functioning in patients undergoing cataract surgery in India.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mapping standard ophthalmic outcome sets to metrics currently reported in eight eye hospitals

BACKGROUND To determine alignment of proposed international standard outcomes sets for ophthalmic conditions to metrics currently reported by eye hospitals. METHODS Mixed methods comparative benchmark study, including eight eye hospitals in Australia, India, Singapore, Sweden, U.K., and U.S. All are major international tertiary care and training centers in ophthalmology. Main outcome measure ...

متن کامل

Correlation of Single Assessment Numeric Evaluation (SANE) with other Patient Reported Outcome Measures (PROMs)

Background: The Single Assessment Numeric Evaluation (SANE) is a simple, one-question patient-reported outcomemeasure (PROM). We systematically reviewed correlations between SANE and more extensive PROMs.Methods: We identified studies with correlation coefficients between SANE and other shoulder, knee, and anklespecificPROMs. We calculated mean, median and range across studies...

متن کامل

Comparison of Anesthesia with Sevoflurane and Propofol on Extubation time and Recovery Parameters During Cataract Surgery

Background: One of the most common outpatient surgeries is cataract surgery which requires a short anesthesia with fast recovery time providing minimal complications. This study aimed to compare sevoflurane with propofol in terms of extubation time and recovery parameters in patients undergoing cataract surgery. Materials and Methods: This randomized controlled clinical trial recruited 60 ...

متن کامل

Research Monitoring visual outcome of cataract surgery in India

Two simple methods of assessing visual outcome following cataract surgery were evaluated in India. The first used data obtained from standardized patient records of cataract surgery. The second used data from population-based rapid epidemiological assessments. Analysis of 4168 hospital and eye camp records showed that, with the available standard correction, a good outcome (visual acuity 56/18)...

متن کامل

The challenges in improving outcome of cataract surgery in low and middle income countries

Cataract is the leading cause of blindness globally and surgery is the only known measure to deal with it effectively. Providing high quality cataract surgical services is critical if patients with cataract are to have their sight restored. A key focus of surgery is the outcome of the procedure. In cataract surgery this is measured predominantly, using visual acuity. Population- and hospital-ba...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2018