[Real time 3D echocardiography in congenital heart disease].

نویسندگان

  • P Acar
  • Y Dulac
  • A Taktak
  • M Villacèque
چکیده

The introduction of the 3D mode in echocardiography has led to its use in everyday clinical practice. One hundred and fifty real time 3D echocardiographic examinations were performed in 20 foetus, 110 children and 20 adults with various congenital heart lesions (shunts, valvular lesions, aortic diseases). The 4x matricial probe enables the instantaneous acquisition of transthoracic volumes. Four modes of 3D imaging were used: real time, total volume, colour Doppler and biplane. Quantitative measurements were performed at an outlying station. The feasibility of the method in the foetus, the child and the adult was respectively 90%, 99% and 85%. Real time 3D echocardiography did not affect the diagnoses made by standard echocardiography. The 3D imaging gave a more accurate description of atrial septal defects and congenital valvular lesions. Biplane imaging was decisive in the quantitative approach to aortic dilatation of Marfan's syndrome and in segmental analysis of the foetal heart. 3D colour Doppler imaging has been disappointing but the possibilities of volumic quantification of blood flow are very promising. The present limitations of the method are the inadequate resolution in the small child and the absence of quantitative measurement on the echograph. The facility of utilisation of the matricial probe should lead to routine usage of 3D echocardiography as with 2D and the Doppler modes. Its value should be decisive in many congenital cardiac lesions requiring surgery or interventional catheterisation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative study of pulse oximetry, physical examination and echocardiography results in the diagnosis of congenital heart defects in neonates in the first 24 hours of life

Introduction: Congenital heart disease is the most common congenital anomaly. About 50% of Neonates with congenital heart disease are asymptomatic in the first few days of life and are not diagnosed on initial examination. Pulse oximetry is a non-invasive method that can show the percentage of oxygen saturation in the blood and congenital heart disease. Methods: This was a descriptive cross-se...

متن کامل

Real-Time 3D echocardiography in a young adult with idiopathic dilatation of the pulmonary artery: a case report.

Idiopathic dilatation of the pulmonary artery (IDPA) is an uncommon anomaly occurring in 0.6% of patients with congenital heart disease. IDPA is characterized by the enlargement of the main pulmonary artery with or without dilatation of the right and left pulmonary arteries. We describe 2D and Real-Time 3D Echocardiography findings in a young adult with IDPA. To the best of our knowledge this i...

متن کامل

Echocardiography: the transition from master of the craft to admiral of the fleet.

Echocardiography has become essential for the diagnosis and management of cardiovascular disease. Over my medical career, cardiac ultrasound has evolved from the blurry wavy lines of M-mode tracings understandable only to a few dedicated practitioners, to real-time intuitive anatomic images accessible to all healthcare providers. In addition, the development and validation of quantitative imagi...

متن کامل

Echocardiographic Evaluation in Neonates Suspected to Congenital Heart Disease in NICU

Background and Objective: Congenital heart disease (CHD) is the most form of cardiovascular disease in children. CHD have different presentations, from defects that progress asymptomatically to those with significant symptoms and high mortality. This study was performed to highlight the importance of signs and symptoms to diagnosis of CHD neonates. Materials & Methods: This descriptive analyt...

متن کامل

Real-time three-dimensional foetal echocardiography using a new transabdominal xMATRIX array transducer.

BACKGROUND Foetal echocardiography has been used to diagnose congenital heart disease. However, conventional echocardiography can only display two-dimensional (2D) structural images of the intricate three-dimensional (3D) foetal heart. AIM The purpose of this study was to report the first use of a new transabdominal xMATRIX array transducer and to describe its ability to perform all 3D modali...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives des maladies du coeur et des vaisseaux

دوره 97 5  شماره 

صفحات  -

تاریخ انتشار 2004