Optimal Intervertebral Sealant Properties for the Lumbar Spinal Disc: A Finite-Element Study

نویسندگان

  • Scott Holekamp
  • Vijay Goel
  • Hiroshi Kuroki
  • Janet Huntzinger
  • Nabil Ebraheim
چکیده

BACKGROUND In the lumbar spinal column, an annular disruption may be sealed after annulotomy to prevent further prolapse and instability. We investigated the biomechanical effects of various material properties of an injectable sealant. METHODS We used a 3-dimensional, nonlinear, osteoligamentous, experimentally validated finite-element model of the L3-L5 spine segment to study annulotomies of varying sizes and locations in the L3-L4 annulus followed by replacement with isotropic sealants (plugs) with a Young's modulus of 0.4, 2.0, 4.0, 6.0, and 40.0 MPa. Annulotomies in the region of the posterior longitudinal ligament were studied with and without the ligament in place. Intact, destabilized, and repaired models were subjected to 400 N compression and 12.7 Nm moment in all loading modes to compute plug forces, plug stresses, motion characteristics, and annulus bulge. RESULTS Changes in sealant stiffness minimally affected the overall motion characteristics of the segment. Increases in shear stress and von Mises stress were proportional to the stiffness of the sealant. The von Mises stress was inversely proportional to plug size. Removal of portions of the posterior longitudinal ligament did not significantly alter motion between spinal segments or stress in the annulus fibrosus. Removal of portions of the ligament increased the disc bulge when plugs were less stiff. Intradiscal pressure decreased when an annulotomy was created. The sealant generally restored nucleus pressure to a degree proportionate to sealant stiffness. CONCLUSIONS Minimizing sealant stresses as well as expulsion and separation forces should lead to a minimal Young's modulus. Sealant materials with a Young's modulus close to 6 MPa are most appropriate. The allowable variation in material properties is reduced with increased annulotomy size. Removal of posterior longitudinal ligament only allows increased sealant bulge when the sealant's modulus of elasticity is very low. This removal does not affect spinal unit biomechanics or annulus stress in annulotomy or annulotomy with sealant repair.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study

Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...

متن کامل

Comparison the Recurrence Rate of Intervertebral Disc Herniation in Two Surgical Methods of Hemi laminectomy and Partial Laminectomy

Background & Aims: Between 5% and 15% of patients with low back pain suffer from lumbar disc herniation, so intervertebral disc disease is one of the most common causes of low back pain. Surgical intervention for lumbar disc herniation is recommended in patients with severe symptoms and has hopeful results. Although surgery can reduce pain and improve physical function in the short term, its lo...

متن کامل

Study on Lumbar Vertebrae Biomechanical Characteristics for Speed Skating Athlete Based on Finite Element Method

Objective: To establish the three-dimensional finite element model of lumbar motion segment (L4-L5) that considers material property and geometrical behave, to investigate mechanical characteristics of lumbar spinal motion segment for application of prevention and reduction of lumbar trauma for the speed skating athletes. Methods: three-dimensional finite element model (FEM) of the human lumbar...

متن کامل

A Finite Element Study of the effects of Vibrational Loading on the Fluid Flow Mechanism of the Intervertebral Disc

Low back pain is a clinical and public health problem affecting more than half of the population. Disc degeneration is a major source of low back pain. Long-term exposure to whole body vibration or sedentary work postures may have high association with disc degeneration. It is hypothesized that there is a preferential frequency for vibrational loading, which may increase the efficiency for flui...

متن کامل

Design of an Elastic Arthroplastic Disc Optimized under Different Loads

Introduction: Due to limitations of current treatments for degenerative disc disease, arthroplastic methods to repair the diseased disc have been proposed. The artificial disc is a mobile implant for degenerative disc replacement that attempts to lessen the degeneration of the adjacent elements following interbody fusion procedures. Because the success of artificial disc replacement depends on ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2007