Comparison of spiral-in/out and spiral-out BOLD fMRI at 1.5 and 3 T.

نویسندگان

  • Alison R Preston
  • Moriah E Thomason
  • Kevin N Ochsner
  • Jeffrey C Cooper
  • Gary H Glover
چکیده

Spiral-in/out functional magnetic resonance imaging (fMRI) methods acquire one image before the echo time (TE) and a second image after TE during each scan. Weighted combination of the two images provides a time series with reduced susceptibility dropout in frontal and medial temporal regions as well as increased signal-to-noise ratio (SNR) in regions of uniform cortex. In this study, task activation with the spiral-in/out method was compared to that with conventional spiral-out acquisitions at two field strengths (1.5 and 3.0 T) using episodic memory encoding, verbal working memory, and affective processing tasks in eight human volunteers. With the conventional spiral-out sequence, greater signal dropout is observed in lateral and medial prefrontal, amygdalar, and medial temporal regions at 3 T relative to 1.5 T, whereas such dropout at 3 T is reduced or mitigated with the spiral-in/out method. Similarly, activation volumes for frontal, amygdalar, and medial temporal regions are reduced for spiral-out acquisitions relative to spiral-in/out, and this difference is more apparent at 3 T than at 1.5 T. In addition, significant regionally specific increases in Z scores are obtained with the spiral-in/out sequence relative to spiral-out acquisitions at both field strengths. It is concluded the spiral-in/out sequence may provide significant advantages over conventional spiral methods, especially at 3 T.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Resolution GRE BOLD fMRI Using Multi-Shot Interleaved Spiral In/Out Acquisition

FIG. 2. Activation maps (p<0.01) evoked using visual stimulus were acquired at high spatial resolution (0.94x0.94x2mm) (left). Six contiguous slices out of 15 are shown. Activation areas are well localized in the occipital lobe. Activation maps (p<0.01) at three orthogonal planes from the memory task at high resolution (1.46x1.46x1.4mm) (right).Well-defined activation can be observed in the par...

متن کامل

Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts.

BOLD fMRI is hampered by dropout of signal in the orbitofrontal and parietal brain regions due to magnetic field gradients near air-tissue interfaces. This work reports the use of spiral-in trajectories that begin at the edge of k-space and end at the origin, and spiral in/out trajectories in which a spiral-in readout is followed by a conventional spiral-out trajectory. The spiral-in trajectory...

متن کامل

Improved combination of spiral-in/out images for BOLD fMRI.

Acquisitions with the spiral-in/out technique result in two separate image timeseries obtained during the spiral-in and spiral-out trajectory. In uniform brain regions the two components have comparable signal and BOLD contrast and can be averaged, but in regions compromised by susceptibility effects where both signal and noise can differ in the two images other combination methods may be more ...

متن کامل

Comparison of 3D BOLD functional MRI with spiral acquisition at 1.5 and 4.0 T.

In order to investigate the merit of high field strength for BOLD-contrast-based functional magnetic resonance imaging (fMRI) studies, multishot gradient-echo fMRI experiments during motor cortex activation were performed on 1.5- and 4.0-T scanners with equivalent hardware, on the same volunteers. In these studies, artifactual vascular enhancement related to inflow effects was minimized, and la...

متن کامل

Fabrication of Saddle-Shaped Surfaces by Flame Forming Process

The flame forming process is widely used to manufacture ship hull plates. The saddle-shaped surfaces have different curvatures in perpendicular angles of planes and the manufacturers face an anti-clastic curvature. In this article, the manufacturing of saddle-shaped surfaces utilizing the flame forming process is investigated. The spiral irradiating scheme is used for forming. In order to study...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • NeuroImage

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2004