Noninvasive detection of coronary artery stenosis using contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography.
نویسندگان
چکیده
OBJECTIVES The purpose of this study was to evaluate a contrast-enhanced three-dimensional (3D) breath-hold magnetic resonance (MR) technique for detection of coronary artery stenoses. BACKGROUND The accuracy of previously published MR coronary angiography protocols varies widely. Recently, coronary artery imaging using T1-shortening contrast agent has become possible, but so far there are no data concerning its clinical application. METHODS Magnetic resonance coronary angiography was performed in 50 patients with suspected coronary artery disease. Magnetic resonance data acquisition using an ultrafast 3D gradient-echo sequence lasted over 32 heartbeats within one single breath-hold. Twenty milliliters of gadopentetate dimeglumine was injected at a flow rate of 1 ml/s for two successive studies covering the main coronary arteries in single-oblique planes. Stenosis assessment by MR was compared with significant (diameter stenosis > 50%) stenoses on X-ray angiography. Evaluation was limited to the proximal and mid-coronary artery segments. RESULTS Two hundred sixty-eight of 350 artery segments (76.6%) could be evaluated. Left circumflex coronary artery was only evaluable in 50% of cases by MR. In the evaluable segments, 48 of 56 stenoses and 193 of 212 nonstenotic segments were correctly classified by MR. On a patient basis, MR correctly identified 34 of 36 patients with and 8 of 14 patients without significant coronary stenoses as demonstrated by X-ray angiography (sensitivity 94.4%, specificity 57.1%). CONCLUSIONS Oblique projection contrast-enhanced MR coronary angiograms obtained within one single breath-hold permit identification of patients with coronary stenoses in the proximal and mid segments of the major coronary arteries with satisfactory accuracy.
منابع مشابه
Automated coronary artery tracking in contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0T
Background Contrast-enhanced whole heart coronary Magnetic Resonance Angiography (MRA) at 3.0 Tesla (T) allows noninvasive detection of obstructive stenoses. Automated vessel segmentation and tracking of centerlines is important for quantitative measurement of stenosis, but remains challenging for coronary MRA. We aimed to develop and validate automated coronary artery segmentation from contras...
متن کاملThree-dimensional magnetic resonance coronary angiography using a new blood pool contrast agent: initial experience.
OBJECTIVE The aim of this feasibility study was to assess the effect of a new blood pool contrast agent on magnetic resonance coronary angiography (MRCA) in patients suspected of having coronary artery disease. METHODS Nine patients referred for diagnostic x-ray coronary angiography in the evaluation of chest pain underwent MRCA using a thin-slab three-dimensional (3D) breath-hold segmented g...
متن کاملDetection of coronary stenoses with contrast enhanced, three-dimensional free breathing coronary MR angiography using the gadolinium-based intravascular contrast agent gadocoletic acid (B-22956).
PURPOSE To determine the diagnostic value of the intravascular contrast agent gadocoletic acid (B-22956) in three-dimensional, free breathing coronary magnetic resonance angiography (MRA) for stenosis detection in patients with suspected or known coronary artery disease. METHODS Eighteen patients underwent three-dimensional, free breathing coronary MRA of the left and right coronary system be...
متن کاملFat-suppressed breath-hold magnetic resonance coronary angiography.
BACKGROUND The ability to image the coronary arteries noninvasively would represent an advance in patient care. We have developed a magnetic resonance (MR) angiographic technique that allows the acquisition of complete images of coronary flow within a single breath-hold. By this method, the feasibility of noninvasive MR coronary angiography was evaluated in 25 subjects, including 19 healthy adu...
متن کاملBreath-hold imaging of the coronary arteries using quiescent-interval slice-selective (qiss) magnetic resonance angiography - pilot study at 1.5 tesla and 3 tesla
BACKGROUND Coronary magnetic resonance angiography (MRA) is usually obtained with a free-breathing navigator-gated 3D acquisition. Our aim was to develop an alternative breath-hold approach that would allow the coronary arteries to be evaluated in a much shorter time and without risk of degradation by respiratory motion artifacts. For this purpose, we implemented a breath-hold, non-contrast-enh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 36 1 شماره
صفحات -
تاریخ انتشار 2000