A repositionable valved stent for endovascular treatment of deteriorated bioprostheses.

نویسندگان

  • Rachid Zegdi
  • Ziad Khabbaz
  • Nicolas Borenstein
  • Jean-Noël Fabiani
چکیده

OBJECTIVES We report our animal experience of endovascular valve replacement (VR) of failed bioprosthesis (BP) using an original delivery catheter allowing repositioning of the valved stent (VS). BACKGROUND Among the different devices designed for percutaneous VR, none has the potential for repositioning of a fully deployed VS. METHODS Five sheep underwent, on beating heart, tricuspid VR with a stented BP. Prolapse of 1 leaflet was induced by tearing. For the endovascular tricuspid VR, we used a VS constructed with a nitinol self-expandable stent and a porcine stentless aortic valve. We also used an original delivery catheter, allowing repositioning of the VS through a compression or relaxation mechanism of the stent. RESULTS Epicardial echocardiography and right ventriculography showed severe tricuspid regurgitation, with a regurgitant jet extending to the inferior vena cava. After surgical exposure to the infrarenal inferior vena cava, the VS was successfully implanted inside the failed BP in all cases. Repositioning of the fully deployed VS was always possible. Echocardiographic and macroscopic studies revealed adequate VS positioning, excellent leaflet opening, and absence of any intraprosthetic or periprosthetic leak. CONCLUSIONS Endovascular VR was easily performed in sheep with failed BP in the tricuspid position. The novel delivery catheter allowed adequate repositioning of our fully deployed VS before its definitive release. One may anticipate that the safety improvement conferred by this new technology will certainly favor the development of percutaneous VR in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioprosthetic replacement of the ascending thoracic aorta: what are the options?

Increasing patient age and improved durability of latest generation bioprostheses have stimulated the use of bioprosthetic devices in the setting of ascending aortic replacement as an alternative to mechanical valved conduits or aortic valve-sparing procedures. We performed an English literature review to assess different surgical options that have been described for bioprosthetic replacement o...

متن کامل

Percutaneous valve replacement: a novel low-profile polyurethane valved stent.

Fig. 1. (a) Oblique view from top of a self-expanding nitinol stent (length 28 mm, diameter 24 mm, Nitinol Devices & Components Inc., Fremont, CA, USA) containing a three leaflet polyurethane valve. Leaflets have a thickness of approximately 100—150 mm. The stent valves are produced in a dip coating technique (by Mecora GmbH, Aachen, Germany). (b) Low-profile polyurethane valved stent was folde...

متن کامل

Percutaneous valved stent implantation in the ascending aorta for the treatment of very high-risk aortic regurgitation: an animal study.

PURPOSE We investigated the effects of percutaneous valved stent implantation in the ascending aorta as an alternative treatment for aortic regurgitation in a canine model. MATERIALS AND METHODS A total of 16 healthy dogs weighing an average of 18.3 ± 2.1 kg were used for the establishment of animal models of chronic aortic regurgitation by percutaneous aortic valve perforation and balloon di...

متن کامل

Subclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis

Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...

متن کامل

Percutaneous valved stent implantation above the coronary ostia.

BACKGROUND In recent years, some experimental and clinical studies on transcatheter aortic valve implantation (TAVI) have been conducted. TAVI is indicated in patients with calcified pure or predominant aortic stenosis. The risk of this technique is still high. Aortic valved stent implantation above the coronary ostia might avoid blocking the coronary ostia. METHODS AND RESULTS Twenty healthy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 48 7  شماره 

صفحات  -

تاریخ انتشار 2006