Comparison of arterial spin labeling and bolus perfusion-weighted imaging for detecting mismatch in acute stroke.

نویسندگان

  • Greg Zaharchuk
  • Ibraheem S El Mogy
  • Nancy J Fischbein
  • Gregory W Albers
چکیده

BACKGROUND AND PURPOSE The perfusion-weighted imaging (PWI)-diffusion-weighted imaging (DWI) mismatch paradigm is widely used in stroke imaging studies. Arterial spin labeling (ASL) is an alternative perfusion method that does not require contrast. This study compares the agreement of ASL-DWI and PWI-DWI mismatch classification in patients with stroke. METHODS This was a retrospective study drawn from all 1.5-T MRI studies performed in 2010 at a single institution. Inclusion criteria were: symptom onset<5 days, DWI lesion>10 mL, and acquisition of both PWI and ASL. DWI and PWI time to maximum>6 seconds lesion volumes were determined using automated software. Patients were classified into reperfused, matched, or mismatch groups. Two radiologists classified ASL-DWI qualitatively into the same categories blinded to DWI-PWI. Agreement between both individual readers and methods was assessed. RESULTS Fifty-one studies met the inclusion criteria. Seven cases were excluded (1 due to PWI susceptibility artifact, 2 due to motion, and 4 due to severe ASL border zone sign), resulting in 44 studies for comparison. Interrater agreement for ASL-DWI mismatch status was high (κ=0.92; 95% CI, 0.80-1.00). ASL-DWI and PWI-DWI mismatch categories agreed in 25 of 44 cases (57%). In the 16 of 19 discrepant cases (84%), ASL overestimated the PWI lesion size. In 34 of 44 cases (77%), they agreed regarding the presence of mismatch versus no mismatch. CONCLUSIONS Mismatch classification based on ASL and PWI agrees frequently but not perfectly. ASL tends to overestimate the PWI time to maximum lesion volume. Improved ASL methodologies and/or higher field strength are necessary before ASL can be recommended for routine use in acute stroke.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arterial spin labeling versus bolus-tracking perfusion in hyperacute stroke.

BACKGROUND AND PURPOSE Arterial spin labeling (ASL) is a perfusion magnetic resonance imaging (MRI) technique that does not require contrast administration and thus may be more practical in hyperacute stroke than susceptibility-weighted bolus-tracking perfusion-weighted imaging (PWI). However, a threshold for ASL measurement of the ischemic penumbra needs to be determined. METHODS A total of ...

متن کامل

Pseudocontinuous arterial spin labeling quantifies relative cerebral blood flow in acute stroke.

BACKGROUND AND PURPOSE The aim of this study was to test whether arterial spin labeling (ASL) can detect significant differences in relative cerebral blood flow (rCBF) in the core, mismatch, and reverse-mismatch regions, and whether rCBF values measured by ASL in those areas differ from values obtained using dynamic susceptibility contrast (DSC) MRI. METHODS Acute stroke patients were imaged ...

متن کامل

Multi-delay multi-parametric arterial spin-labeled perfusion MRI in acute ischemic stroke — Comparison with dynamic susceptibility contrast enhanced perfusion imaging☆

The purpose of the present study was to present a multi-delay multi-parametric pseudo-continuous arterial spin labeling (pCASL) protocol with background suppressed 3D GRASE (gradient and spin echo) readout for perfusion imaging in acute ischemic stroke. PCASL data at 4 post-labeling delay times (PLD = 1.5, 2, 2.5, 3 s) were acquired within 4.5 min in 24 patients (mean age 79.7 ± 11.4 years; 11 ...

متن کامل

Arterial Spin Labeling Perfusion Magnetic Resonance Imaging Performed in Acute Perinatal Stroke Reveals Hyperperfusion Associated With Ischemic Injury.

BACKGROUND AND PURPOSE Perfusion-weighted imaging in adults with acute stroke often reveals hypoperfusion in the ischemic core and in a surrounding area of nondiffusion-restricted penumbral tissue. Perinatal stroke is common, but the perfusion pattern is rarely documented. We aimed to describe the perfusion pattern in newborns with perinatal stroke. METHODS Neonates with clinical features of ...

متن کامل

Quantitative analysis of hypoperfusion in acute stroke: arterial spin labeling versus dynamic susceptibility contrast.

BACKGROUND AND PURPOSE This study compares the concordance between arterial spin labeling (ASL) and dynamic susceptibility contrast (DSC) for the identification of regional hypoperfusion and diffusion-perfusion mismatch tissue classification using a quantitative method. METHODS The inclusion criteria for this retrospective study were as follows: patients with acute ischemic syndrome with symp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 43 7  شماره 

صفحات  -

تاریخ انتشار 2012