Evaluation of Strained-Silicon by Electron Backscattering Pattern Measurement: Comparison Study with UV-Raman Measurement and Edge Force Model Calculation
نویسندگان
چکیده
منابع مشابه
Evaluation putty metal as internal shield for patient protection of electron therapy by Monte Carlo study
Introduction: In this study, a specific combination (70% W 18.61% Ni and 11.39% C) of lead free and flexible putty metal is introduced and validated as internal shielding by Mont Carlo study Materials and Methods: To evaluate putty metal as an internal shielding by Mont Carlo study Varian 2100 C/D was validated within measurement and then by given energy spect...
متن کاملDiscrimination of Geological Top-Formations by their Morphology through SAR Images and via Fractal Geometry implementation in IEM Backscattering Model(Case Study: Zagros Thrust Belt)
Morphological discrimination of geological top-formations is the supplemental procedure of geological mapping; so in situ measurements to register geomorphological data are unavoidable; though due to the impassable and fault cliffs field operations to visit all areas within a geological map is almost impossible. Microwave or radar remote sensing, via synthetic aperture radar (SAR) images is cap...
متن کاملRaman spectroscopy study of nano sheets of graphene and measurement of their resistivity
Graphene is a promising candidate for future high-speed electronics applications. It is a thin layer of pure carbon in which every atom is available for chemical reaction from two sides (due to the 2D structure). This is the only form of carbon (or solid material) with this characteristic feature. Graphene oxide (GO) was synthesized through the oxidation of graphite using the Hummer’s method, i...
متن کاملStrained-Si heterostructure field effect transistors
The purpose of this review article is to report on the recent developments and the performance level achieved in the strained-Si/SiGe material system. In the first part, the technology of the growth of a high-quality strained-Si layer on a relaxed, linear or step-graded SiGe buffer layer is reviewed. Characterization results of strained-Si films obtained with secondary ion mass spectroscopy, Ru...
متن کاملEvaluation of Dose Calculation Accuracy of Isogray Treatment Planning System in Craniospinal Radiotherapy
Introduction: Craniospinal radiotherapy is a therapeutic technique for central nervous system (CNS) tumors, which requires meticulous attention to technique and dosimetry.Treatment planning system (TPS) is one of the main equipment in radiotherapy; therefore, the evaluation of its accuracy is essential for dose calculation. The present study evaluates the validity of Isogray TPS in craniospinal...
متن کامل