An Evaluation of Xrd and Xrf Methods Used in an Aluminium Bath
نویسندگان
چکیده
The paper deals with the application of X-ray fluorescence and diffraction for the routing control of a chemical content of an electrolysis cell in aluminum reduction plants. Among two approaches XRD meets technological requirements on accuracy, time limit and the cost of analysis. XRF demonstrates insufficient accuracy because of sample preparation problem.
منابع مشابه
An Evaluation of Xrd and Xrf Methods Used in an Aluminium Bath Analysis
The paper deals with the application of X-ray fluorescence and diffraction for the routing control of a chemical content of an electrolysis cell in aluminum reduction plants. Among two approaches XRD meets technological requirements on accuracy, time limit and the cost of analysis. XRF demonstrates insufficient accuracy because of sample preparation problem.
متن کاملThermal Analysis: A Complementary Method to Study the Shurijeh Clay Minerals
Clay minerals are considered the most important components of clastic reservoir rock evaluation studies. The Shurijeh gas reservoir Formation, represented by shaly sandstones of the Late Jurassic-Early Cretaceous age, is the main reservoir rock in the Eastern Kopet-Dagh sedimentary Basin, NE Iran. In this study, X-ray diffraction (XRD), X-ray fluorescence (XRF), scanning electron microscopic (S...
متن کاملA Portable Non-invasive Xrd-xrf Instrument for the Study of Art Objects
A non-invasive XRD/XRF instrument for study of works of art has been developed jointly by the Getty Conservation Institute and inXitu Inc. (California). Many aspects of the instrument are based on technologies initially developed for NASA’s planetary XRD/XRF instrument CheMin and used in inXitu’s portable transmission XRD/XRF instrument (Terra). A new geometry was designed based on a reflection...
متن کاملDispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop as an Efficient Preconcentration Method for Spectrophotometric Determination of Aluminium
A rapid, simple, and sensitive dispersive liquid-liquid microextraction based on solidification of floating organic drop (DLLME-SFOD) method coupled with UV–Vis spectrophotometry has been applied for the extraction and determination of trace amounts of aluminium. The aluminium was extracted from the aqueous media containing aluminon and cetyltrimethylammonium bromide (CTAB). After rapid injecti...
متن کاملA sol-gel based method for preparation of Ni/La-Al2O3 as a new catalyst for dechlorination of monochlorobenzene
In this study, two new Ni/La-Al2O3 catalysts were prepared by a sol-gel method, with different aluminium precursors (aluminium triisopropoxide and aluminium nitrate). The catalysts were characterized by scanning electron microscope (SEM), X-ray fluorescence (XRF), X-ray diffraction (XRD), BET specific surface area, and particle size analysis (PSA) techniques. The BET results showed that the par...
متن کامل