Evaluation of Holmium:YAG Laser Optical Fibers for Flexible Ureteroscopy using a Relevant Benchtop Model

نویسنده

  • Jacky G. Duchamp
چکیده

Materials and Methods. Testing was conducted on single-use and reusable laser fibers in varying sizes – 200μm, 272μm, 365μm, 550μm and 1000μm. Sizes reflect the true core diameter of each fiber. Fixtures for the testing were built for the 200μm, 272μm, 365μm, 550μm fibers simulating the anatomical curvature that the fiber may be subjected to during a procedure (considered the short-term bend radius), as well as the maximum-allowed deflection of the fiber when placed within the working channel of a flexible ureteroscope. A separate fixture was built for the 1000μm fiber simulating the short-term bend radius only, as its core size does not allow for deflection or use within a flexible ureteroscope. Each fiber was placed into its respective fixture, and power outputs were recorded using the HeNe laser JDSU Model 1137 and Lumenis VersaPulse 100W PowerSuite Holmium:YAG laser generator. The SMA-905 connector of each fiber was first connected to the HeNe laser to determine the fiber’s spot size, and the power output was recorded. The fiber was subsequently connected to the Lumenis VersaPulse 100W PowerSuite Holmium:YAG laser generator, and the generator was set to the maximum-allowed power input for each fiber per the Instructions for Use. The power output was then recorded. Further tests were performed on the reusable fibers following cleaving, stripping, cleaning and resterilization, and following transportation and extreme conditioning, and aging. Tests were also carried out on non-sterile laser fibers to evaluate the complete downstream process effect study. To pass testing, the laser fibers had to meet the acceptance criteria of transmitting 80% or greater of the maximum power inputs for both the HeNe and Holmium:YAG lasers. Acceptance criteria also included no known nonconformances reported with either the laser fiber or the laser generator.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a New 240-lm Single-Use Holmium:YAG Optical Fiber for Flexible Ureteroscopy

Background and Purpose: Numerous holmium:yttrium-aluminum-garnet laser fibers are available for flexible ureteroscopy. Performance and durability of fibers can vary widely among different manufacturers and their product lines with differences within a single product line have been reported. We sought to evaluate a newly developed nontapered, single-use 240-lm fiber, Flexiva 200 (Boston Scientif...

متن کامل

Evaluation of a new 240-μm single-use holmium:YAG optical fiber for flexible ureteroscopy.

BACKGROUND AND PURPOSE Numerous holmium:yttrium-aluminum-garnet laser fibers are available for flexible ureteroscopy. Performance and durability of fibers can vary widely among different manufacturers and their product lines with differences within a single product line have been reported. We sought to evaluate a newly developed nontapered, single-use 240-μm fiber, Flexiva™ 200 (Boston Scientif...

متن کامل

Antegrade Flexible Ureteroscopy for Bilateral Ureteral Stones in a Patient with Severe Hip Joint Ankylosis

In the past several decades there has been a remarkable development of small-caliber, flexible ureteroscopes and various ancillary instruments for stone manipulation and retrieval. Percutaneous antegrade ureteroscopy can be substituted in select cases for retrograde ureteroscopy. We report a case of a 60-year-old man with severe ankylosis in both hip joints who was diagnosed with bilateral uret...

متن کامل

Flexible ureteroscopy and holmium:YAG laser lithotripsy for stone disease in patients with bleeding diathesis: a systematic review of the literature.

INTRODUCTION AND OBJECTIVES The management of urolithiasis in patients on anticoagulants presents a challenge to the endourologist. Due to multiple comorbidities, it may be impossible to safely discontinue the anticoagulant treatment. Other modalities such as shock wave lithotripsy and PCNL are contraindicated in these patients, so ureteroscopic treatment may be the only option. We conducted a ...

متن کامل

Is the holmium:YAG laser the best intracorporeal lithotripter for the ureter? A 3-year retrospective study.

PURPOSE To study the efficiency and safety of holmium:YAG laser lithotripsy for ureteral stones. PATIENTS AND METHODS A series of 188 patients with 208 ureteral stones were treated with semirigid ureteroscopy and holmium:YAG laser lithotripsy from January 2003 to December 2005. Of the stones, 116 were lower ureteral, 37 middle ureteral, and 55 upper ureteral. RESULTS The success rate was 92...