Incidence of tissue coring during transseptal catheterization when using electrocautery and a standard transseptal needle.

نویسندگان

  • Eugene Greenstein
  • Rod Passman
  • Albert C Lin
  • Bradley P Knight
چکیده

BACKGROUND The application of radiofrequency electrocautery to a standard, open-ended transseptal needle has been used to facilitate transseptal puncture (TSP). The purpose of this study was to determine the incidence of cardiac tissue coring when this technique is used. METHODS AND RESULTS A model using excised swine hearts submerged in a saline-filled basin was developed to simulate TSP with electrocautery and a standard transseptal needle. Punctures were performed without the use of electrocautery and by delivering radiofrequency energy to the transseptal needle using a standard electrocautery pen at 3 target sites (fossa ovalis, non-fossa ovalis septum, and aorta). The tissue of the submerged heart was gently tented, and the needle was advanced on delivery of radiofrequency. The devices were retracted, and the needle was flushed in a collection basin. None of the TSPs without cautery caused tissue coring. For TSPs using electrocautery, the frequency of coring was at least 21% for any puncture permutation used in the study and averaged 37% at septal sites (P<0.001 compared with punctures without cautery). Tissue coring occurred in 33 of 96 (35%) punctures through the fossa ovalis and in 38 of 96 (40%) punctures through non-fossa ovalis septum. The frequency of tissue coring at aortic sites was 62 of 96 (65%), which was significantly higher than at the septal sites (P<0.001). CONCLUSIONS In an animal preparation, TSP at the level of the fossa ovalis using electrocautery and a standard open-ended Brockenbrough needle resulted in coring of the septal tissue in 35% of cases (33 of 96 punctures).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Different transseptal puncture for different procedures: Optimization of left atrial catheterization guided by transesophageal echocardiography

BACKGROUND Left atrial catheterization through transseptal puncture is frequently performed in cardiac catheterization procedures. Appropriate transseptal puncture is critical to achieve procedural success. AIMS The aim of the study is to evaluate the feasibility of selective transseptal punctures, using a modified radiofrequency (RF) transseptal needle and transesophageal echocardiography (T...

متن کامل

The use of a radiofrequency needle improves the safety and efficacy of transseptal puncture for atrial fibrillation ablation.

BACKGROUND Atrial fibrillation (AF) ablation requires transseptal puncture to gain entry to the left atrium (LA). On rare occasions, LA entry cannot be achieved or cardiac perforation results in pericardial tamponade. OBJECTIVE This study sought to compare a new radiofrequency (RF) transseptal needle with the standard needle. METHODS We evaluated 1,550 AF ablations in 1,167 patients. We com...

متن کامل

Radiofrequency puncture of the fossa ovalis for resistant transseptal access.

BACKGROUND Transseptal puncture with a conventional mechanical technique can fail because of a resistant interatrial septum. We evaluated the efficacy and safety of a new method to cross-resistant septae by transmitting radiofrequency (RF) energy through the transseptal needle. METHODS AND RESULTS Among 269 consecutive transseptal punctures, 13 (5%) were unsuccessful in 12 different patients ...

متن کامل

The use of a novel nitinol guidewire to facilitate transseptal puncture and left atrial catheterization for catheter ablation procedures.

AIMS An increasing number of transseptal punctures (TSPs) are performed worldwide for atrial ablations. Transseptal punctures can be complex and can be associated with potentially life threatening complications. The purpose of the study was to evaluate the safety and efficacy of a novel transseptal guidewire (TSGW) designed to facilitate TSPs. METHODS AND RESULTS Transseptal punctures were pe...

متن کامل

[Learning process for transseptal puncture guided by intracardiac echocardiography].

We prospectively analyzed the learning process for transseptal catheterization guided by intracardiac echocardiography, in 50 patients who underwent radiofrequency ablation for left atrial arrhythmias. In 20 patients the intracardiac echocardiography catheter was positioned in the right atrium to visualize the fossa ovalis and the tenting of the fossa caused by the Brockenbrough needle. In the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 2012