Percutaneous retrieval of lost or misplaced intravascular objects.
نویسندگان
چکیده
OBJECTIVE We report on our experience with percutaneous interventional techniques for retrieval of intravascular foreign bodies or repositioning of misplaced endovascular prostheses. MATERIALS AND METHODS Over a period of 6 years, we attempted percutaneous treatment of intravascular foreign bodies in 45 patients. The 45 foreign objects consisted of 12 endovascular stents, 14 catheter fragments, 11 embolization coils, four guidewire fragments, three vena cava filters, and one cardiac valve fragment. Percutaneous extraction was performed using a combination of multipurpose catheters and nitinol snare loop or grasping forceps. Depending on their composition, misplaced or dislodged intravascular stents were either repositioned or percutaneously removed. RESULTS Percutaneous intervention was successful in 41 (91.1%) of 45 patients. Of 38 patients on whom we performed percutaneous removal, the procedure was successful in 34 patients (89.5%), including 13 of the 14 patients with catheter fragments, all four of the patients with guidewire fragments, 10 of the 11 patients with misplaced or dislodged embolization coils, four of the five patients with misplaced or dislodged endovascular stents, and all three of the patients with misplaced or dislodged vena cava filters. The procedure was not successful in the one patient with a cardiac valve fragment. All seven of the percutaneous repositioning procedures we performed resulted in the endovascular stent being successfully repositioned in a stable intravascular position. Most of the retrieval procedures (77.7%) were performed using the nitinol snare as the primary instrument. No late complications were registered during the follow-up period, which ranged from 9 to 68 months (mean, 42.4 months overall). CONCLUSION Percutaneous techniques for the extraction of intravascular foreign objects or for repositioning of dislocated endovascular stents are highly effective with a low rate of complications and should always be the primary method of choice.
منابع مشابه
Percutaneous endovascular retrieval of an intravascular foreign body in five dogs, a goat, and a horse.
CASE DESCRIPTION-5 Dogs, 1 goat, and 1 horse underwent percutaneous endovascular retrieval of intravascular foreign bodies between 2002 and 2007. CLINICAL FINDINGS-Foreign bodies were IV catheters in 4 dogs, the horse, and the goat and a piece of a balloon valvuloplasty catheter in 1 dog. Location of the foreign bodies included the main pulmonary artery (1 dog), a branch of a pulmonary artery (...
متن کاملRemoval of intracardiac fractured port-A catheter utilizing an existing forearm peripheral intravenous access site in the cath lab.
The intravenous port-A catheters are widely used for long-term central venous access in cancer patients. Spontaneous fracture and migration of implanted port catheters is a known complication and necessitates immediate removal. Percutaneous retrieval of intravascular foreign body has become a common practice and is commonly performed through central venous access, mostly using femoral, subclavi...
متن کاملI-4: Sperm Retrieval: 2013 Updates
Men with congenital absence or bilateral partial aplasia of vas deferens, or those with failed or surgically unreconstructable obstructions or azospermic men with testicular failure or genetic cause can now be treated by using sperm retrieval techniques in conjunction with in vitro fertilization/intra cytoplasmic sperm injection (ICSI/ IVF). These techniques are: Microsurgical epididymal sperm ...
متن کاملRetrieval of detached fragment of central venous pressure catheter (CVP) lodged in the right ventricle and pulmonary artery: a case report.
A successful retrieval of a detached segment of a CVP catheter by percutaneous right transfemoral venous route, using a Dotter intravascular retriever basket, is reported. The procedure was monitored under fluoroscopy. Only local anaesthesia, which was infiltrated around the puncture site, was given to the patient. No significant complication was encountered. Successful retrieval of the detache...
متن کاملSniffeer Technology for Mobiles
The cell phone though the mobile communication system is proved to be an advantageous method of communication over wired communication, there is another problem that is the mobile phones get lost or get misplaced. The losses are increasing day by day and there has been very little effort that has been done to obtain the lost mobile phone. The main scope for this paper is “The proposal for the d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJR. American journal of roentgenology
دوره 176 6 شماره
صفحات -
تاریخ انتشار 2001