A comparison of operative field space between sterile single use and re-useable pneumatic tourniquets in revision total knee arthroplasty

نویسنده

  • Morgan - Jones
چکیده

Adequate operative field space minimises potential complications during revision knee arthroplasty. The colonisation rate of pneumatic re-useable devices reported to be 68-78%, other devices should be considered in the revision knee surgery setting. Sterile single use tourniquets devices (Heamaclear® /S-MARTTM, OHK Medical Devices, Haifa, Israel) have colonisation rates of 0%. This study assesses the operative field clearance between the two devices and discusses the potential benefits for reducing infection in revision knee surgery. At the time of revision knee replacement, the operative field space was measured using both pneumatic and sterile single use tourniquets. The measurements were taken once the components had been explanted. The average operative field space increase using a sterile single use tourniquet compared to a multi-use pneumatic device was 8.98 cm [CI95% 7.1-10.8 cm], p<0.001 (p=0.00034). It is recommended that sterile single use tourniquets are safe and are a useful tool for surgeons facilitating ease of revision knee surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcome of revision in comparison with primary total knee arthroplasty in Iran

 Abstract  Background: In the recent decade, many primary total knee arthroplasties have  been carried out in Iran and the number of revision cases is expected to rise with the  aging population. The aim of this study was to report the outcome of revision surgery  in the country and make a comparison between the outcome of revision and that of  the primary arthroplasty.  Methods: Retrospectivel...

متن کامل

Comparison of Clinical Results between Patellar Resurfacing and Non-resurfacing in Total Knee Arthroplasty: A Short Term Evaluation

Background: There is no difference in the functional outcomes 6 months after total knee arthroplasty (TKA) for kneeosteoarthritis between patellar resurfacing and non-resurfacing. Thus, we have performed this study to compare theshort-term clinical outcomes of TKA performed with and without the patella resurfacing.Methods: A total of 50 patients with osteoarthritis of the knee (OAK) were random...

متن کامل

A Comparison of the Postoperative Complications between Two Drainage Methods after Total Knee Arthroplasty

Background: The role of wound drainage after total knee arthroplasty is still considered controversial as althoughclosed drainage systems have been believed to be effective in decreasing the post-operative complications, they couldalso facilitate the bleeding and increase the rate of transfusion and infection. We have conducted the current study tocompare the outcomes superficial subcutaneous, ...

متن کامل

The influence of tourniquet use and operative time on the incidence of deep vein thrombosis in total knee arthroplasty

OBJECTIVE To evaluate the association between tourniquet and total operative time during total knee arthroplasty and the occurrence of deep vein thrombosis. METHODS Seventy-eight consecutive patients from our institution underwent cemented total knee arthroplasty for degenerative knee disorders. The pneumatic tourniquet time and total operative time were recorded in minutes. Four categories w...

متن کامل

Skin protection underneath the pneumatic tourniquet during total knee arthroplasty: a randomized controlled trial of 92 patients.

BACKGROUND The use of a pneumatic tourniquet to obtain a bloodless field during a total knee arthroplasty (TKA) allows the surgeon to work with greater technical precision in a safe, clear environment. Despite the benefits of surgical tourniquets and many advances in tourniquet equipment, their use is not without risk and complications may still occur. The primary aim of this study was to deter...

متن کامل