The revised NASPE/BPEG generic code for antibradycardia, adaptive-rate, and multisite pacing. North American Society of Pacing and Electrophysiology/British Pacing and Electrophysiology Group.

نویسندگان

  • Alan D Bernstein
  • Jean-Claude Daubert
  • Ross D Fletcher
  • David L Hayes
  • Berndt Lüderitz
  • Dwight W Reynolds
  • Mark H Schoenfeld
  • Richard Sutton
چکیده

In light of evolving pacemaker technology and increasing interest in multisite pacing, the Committee on the Development of Position Statements (CDPS) of the North American Society of Pacing and Electrophysiology (NASPE) created an ad hoc Pacemaker Mode Code Task Force in April 2001 under the chairmanship of David L. Hayes, MD, for the purpose of bringing the NASPE/British Pacing and Electrophysiology Group (BPEG) Generic Pacemaker Code (NBG Code) up to date. The task force, whose members are the authors of this article, designed a revised NBG Code in which three major issues were taken into account. First, it was recognized that all modern pacemakerpulse generators are capable of extensive bidirectional communication with an external programming device, making them "communicating" pulse generators as defined by the current (1987) NBG Code. Second, it was decided that a means of providing basic information regarding the location of multisite pacing would be a useful ingredient of the NBG Code. Third, in view of the extensive antibradycardia pacing capabilities common in modern implantable cardioverter defibrillators and the availability of the NASPE/BPEG Defibrillator Code (NBD Code), it was considered unnecessary for the NBG Code to address the presence or absence of antitachycardia features. The resulting updated version of the NBG Code as described herein was endorsed by the BPEG on September 20, 2001 and adopted by the NASPE Board of Trustees on October 18, 2001. The structure of the revised NBG Code differs from that of the previous version in two respects alone: Position IV specifies only the presence or absence of rate modulation, and Position V specifies only the location or absence of multisite pacing (i.e., biatrial or biventricular pacing with at least two stimulation sites in each case) more than one stimulation site in any single cardiac chamber, or any combination of these. The revised NBG Code is deliberately configured to avoid confusion with earlier mode codes, and it is the authors' hope that it will serve as an enhanced resource for communication among those engaged in every phase of the multidisciplinary practice of cardiac rhythm management.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simple new code for multisite cardiac pacing and implantable cardioverter defibrillator.

edigraphic.com ost pacemakers of the 1960’s presented no problem for the description of their functions because they were all essentially the same: they paced a single cardiac chamber, had no sensing capability and had no adjustable characteristics. For the first time, in 1974 the Inter-Society Commission for Heart Disease (ICHD) proposed a three-position “generic” or “conventional” pacemaker c...

متن کامل

Cardiac rhythm management devices (part II): perioperative management.

IN the first installment of this two-part communication, we reviewed the indications for an implanted pacemaker or internal cardioverter–defibrillator (ICD), provided a brief overview of how a device is selected, and described the basics of pacemaker and ICD design and function. Here we discuss specific device malfunction, electromagnetic and mechanical interference, and management for patients...

متن کامل

NASPE training requirements for cardiac implantable electronic devices: selection, implantation, and follow-up.

Cardiac implantable electronic devices (CIEDs) have become frequently used therapeutic modalities. CIEDs include pacemakers, implantable cardioverter defibrillators (ICDs), devices for heart failure management (cardiac resynchronization), and implantable hemodynamic monitors. Selection of the appropriate CIED, its implantation, and follow-up care require expertise to achieve optimal therapeutic...

متن کامل

North American Society of Pacing and Electrophysiology. Standards of professional practice for the allied professional in pacing and electrophysiology.

The North American Society of Pacing and Electrophysiology (NASPE) was established in recognition of the unique challenges that the management of patients with cardiac rhythm disorders present. As with other subspecialty fields within cardiology, the genesis of this specialty evolved from technological innovations and ensuing biomedical applications, which fueled the development of electrophysi...

متن کامل

Acute haemodynamic comparison of multisite and biventricular pacing with a quadripolar left ventricular lead.

AIMS Pacing from multiple sites in the left ventricle (LV) may bring about further resynchronization of the diseased heart compared with biventricular (BiV) pacing. We compared acute haemodynamic response (LV dP/dtmax) of multisite and BiV pacing using a quadripolar LV lead. METHODS AND RESULTS In 21 patients receiving cardiac resynchronization therapy, a quadripolar LV lead and conventional ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 2002