Minimally Invasive Plate Osteosynthesis with Locking Compression Plate for Distal Diametaphyseal Tibia Fracture
ثبت نشده
چکیده
Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology of distal tibia and fracture hematoma and also provides biomechanicaly stable construct.
منابع مشابه
Minimally invasive plate osteosynthesis with locking compression plate for distal diametaphyseal tibia fracture.
BACKGROUND Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology ...
متن کاملComparative study of intramedullary interlocking nailing and minimally invasive percutaneous plate osteosynthesis (MIPO) in extra articular distal tibial fracture
Introduction: Tibia is one of the most commonly fractured long bone of the body. Distal tibia fractures are primarily located within a square based on the width of the distal tibia. Treatment of distal tibia fracture is challenging because of its unique anatomical characteristics of subcutaneous location with precarious blood supply and proximity to the ankle joint. Minimally invasive plate ost...
متن کاملEarly Results of Minimally Invasive Percutaneous Plate Osteosynthesis for Fractures of the Distal Tibia: A Retrospective Case Series and Review of the Literature
Minimally invasive percutaneous plate osteosynthesis was developed on the concept that preservation of the soft tissue envelope during surgical management of distal tibial fractures is of paramount importance. We report on our early experience using this technique over a 1-year period with 14 such injuries that were treated by a locking compression plate via minimally invasive surgery. The surg...
متن کاملMinimally invasive plate osteosynthesis for osteofibrous dysplasia of the tibia: a case report.
Osteofibrous dysplasia occurs most frequently in the tibia and may result in deformity and pathological fracture. We report one such case in a 6-year-old girl who underwent minimally invasive plate osteosynthesis using a locking compression plate. The varus deformity of the tibia was manually corrected, and the plate was inserted without extensive surgical exposure. At 20-week follow-up, the fr...
متن کاملPlate on Plate Technique of Minimally Invasive Percutaneous Plate Osteosynthesis in Distal Tibial Fractures, an Easy and Inexpensive Method of Fracture Fixation
BACKGROUND Plate on plate technique can lessen operative time and patient morbidity. OBJECTIVES This study aimed to evaluate the outcomes of minimally invasive percutaneous plate osteosynthesis (MIPPO) using plate on plate technique of locking plate fixation for closed fractures of distal tibia in a prospective study. PATIENTS AND METHODS Twenty-five patients with distal tibial fractures we...
متن کامل