Nine-Year Follow-Up of Intacs Implantation for Keratoconus
نویسندگان
چکیده
PURPOSE To present a case of nine- year bilateral Intacs (Addition Technology, Inc, Fremont, California, USA) implantation for early stage keratoconus. METHODS A 25-year-old male underwent bilateral Intacs implantation for the management of keratoconus and hardcontact-lens intolerance (stage 1) in 1999. RESULTS Nine years postoperatively, spherical equivalent refraction changed from preoperative -0.75 and -2.25 to +0.75 and -1.25 for the right and the left eye, respectively. UCVA was improved from 20/50 to 20/25 in the right and from 20/200 to 20/32 in the left eye. BSCVA of 20/20 in the right eye maintained stable in comparison with the Pre-Intacs BSCVA, while BSCVA was improved from 20/25 to 20/20 in the fellow eye. No early or late complications were observed. CONCLUSIONS Nine years after bilateral Intacs implantation for the management of early stage keratoconus, there was a significant improvement and postoperative stability in patient's visual acuity. No long-term, sight-threatening complications were identified during follow-up.
منابع مشابه
Keratoconus managed with intacs: one-year results.
OBJECTIVES To describe the visual outcome of keratoconus managed with Intacs implantation (Addition Technology Inc, Fremont, Calif) and to define criteria that predict good outcome. METHODS This retrospective, nonrandomized, comparative, consecutive case series studied 58 eyes of 43 patients with keratoconus managed by Intacs implantation. The outcome measures were analyzed pre-Intacs and 1 y...
متن کاملLate onset of deep corneal vascularization: a rare complication of intrastromal corneal ring segments for keratoconus.
PURPOSE To report deep corneal vascularization noted 3 years after intrastromal corneal ringsegments (Intacs) implantation for the treatment of keratoconus. METHODS A 33-year-old male keratoconus patient intolerant to rigid gas permeable contact lens in the right eye underwent Intacs implantation. At 2 years postoperatively, slit-lamp examination of the right eye revealed superficial corneal ...
متن کاملImplantation of Artisan toric phakic intraocular lens following Intacs in a patient with keratoconus.
We report a 24-year-old man with bilateral keratoconus in whom Intacs (Addition Technology, Inc.) were implanted in both eyes. The procedure was followed by Artisan toric phakic intraocular lens (Ophtec) implantation to correct the residual myopic and astigmatic refractive error.
متن کاملImplantation of intracorneal ring segments in pediatric patients: long-term follow-up
Purpose To analyze the long-term outcomes of intracorneal ring segments (ICRS) implantation for keratoconus management in pediatric patients. Methods Retrospective case series review of the long-term (>5 years) outcomes of Intacs® ICRS implantation for keratoconus in pediatric patients (age <18 years old at the time of surgery) between January 2008 and December 2011 at Ophthalmology Departmen...
متن کاملOutcomes of Single Segment Implantation of Conventional Intacs versus Intacs SK for Keratoconus
PURPOSE To compare the visual, refractive, and keratometric outcomes of single-segment conventional and severe keratoconus (SK) types of Intacs for correction of inferior keratoconus (KCN). METHODS A total number of 41 consecutive eyes of 23 patients with a diagnosis of inferior KCN underwent Intacs implantation. Eight eyes were excluded due to postoperative complications (4 eyes) and loss to...
متن کامل