CLINICAL RESEARCH STUDIES From the New England Society for Vascular Surgery The influence of gender and aortic aneurysm size on eligibility for endovascular abdominal aortic aneurysm repair
نویسندگان
چکیده
Objectives: The purpose of this study was to compare the eligibility of men and women with infrarenal abdominal aortic aneurysms (AAAs) for on-label endovascular aneurysm repair (EVAR) as part of the clinician-Food & Drug Administration (FDA) collaborative effort, the Characterization of Human Aortic Anatomy Project (CHAP). Methods: Computed tomography (CT) scans with 3D reconstruction from a single institution obtained between July 1996 and December 2009, including standardized measurements by a blinded third-party (M2S, West Lebanon, NH) were examined. For inclusion, abdominal aortic aneurysm (AAA) had to be infrarenal, unrepaired, and >5 cm, or 4 cm to 5 cm if the orthogonal sac diameter was more than twice the aortic diameter at the renal level. Scans were included regardless of subsequent EVAR, open repair, or lack of treatment. One thousand sixty-three unique, unrepaired AAAs were analyzed. Results: Neck length, diameter, and angulation differ for women (P < .001) even after adjustment for patient age and AAA size. EVAR eligibility based on device Instructions for Use (IFU) criterion is affected by gender. Neck length <15 mm was found in 47% of men and 63% of women. Neck angulation exceeding 60 degrees was found in 12% of men and 26% of women. Minimum iliac diameter of 6 mm was found in 35% of men and 55% of women. Only 32% of men and 12% of women met all three neck criterion and had iliac lumen diameters >6 mm. Logistic regression modeling shows that older patient age (odds ratio [OR], 0.84 per decade), increased aneurysm diameter (OR, 0.70 per cm), and female gender (OR, 0.4) are each independently associated with decreased odds of meeting all device IFU neck criterion (P < .05). EVAR eligibility by neck criterion does not decline significantly until AAA size exceeds 5.5 cm in women and 6.5 cm in men. Conclusion: Women are significantly less likely to meet device IFU criterion for EVAR. Aortic neck criteria and iliac access are important for men and women, but more women than men fail to meet IFU criterion. Devices that accommodate shorter infrarenal AAA neck length will have the greatest impact on expanding on-label EVAR regardless of gender. Lower profile devices and those that accommodate higher neck angulation are expected to expand EVAR eligibility further for women. EVAR eligibility is unlikely to be lost as AAAs enlarge to 5.5 cm in women and 6.5 cm in men. Observation of small AAAs until they reach the standard threshold size for repair should not compromise EVAR eligibility. ( J Vasc Surg 2011;54:931-7.)
منابع مشابه
Frequency of Complications Following Endovascular Repair of Abdominal Aortic Aneurysm in Tehran Sina Hospital, 2011-2019
Background and purpose: Abdominal aortic aneurysms (AAA) is a localized enlargement of infrarenal abdominal aorta. Endovascular aneurysm repair (EVAR) is a surgical method introduced for AAA repair. This study, for the first time in Iran, investigated the complications and mortality rate associated with EVAR. Materials and methods: In this cross-sectional study, medical records were reviewed...
متن کاملAn Aortoenteric Fistula Arising after Endovascular Management of a Mycotic Abdominal Aortic Aneurysm Complicated with a Psoas Abscess
Mycotic aortic aneurysms account for 1–3% of all aortic aneurysms. The management of this disease is controversial. Since open surgical repair is associated with high morbidity and mortality rates, endovascular aneurysm repair is an alternative treatment method with promising early and midterm outcomes, although its long-term durability is unknown.Secondary aortoenteric fistulas may occur iatro...
متن کاملDrug Therapy for Small Abdominal Aortic Aneurysm
Dear Editor,Abdominal aortic aneurysm is often asymptomatic, less recognized, and causes considerable mortality and morbidity, if missed. The incidence varies from country to country and the occurrence is influenced by modifiable (smoking, coronary heart disease, hypertension, dyslipidemia, and prolonged steroid therapy) and non-modifiable risk factors (increasing age, male gender, and positive...
متن کاملAORTIC TRANSECTION AND ITS SURGICAL REPAIR: A CASE REPORT FROM IRAN
Aortic transection is a rare but life-threatening complication of blunt chest trauma. Treatment options include open repair, medical management and most recently, endovascular repair. We report a 33 years old male with a traumatic aortic transection following a car accident. Aortic injury and its pseudo-aneurysm were confirmed by Chest CT scan and TEE in the descending thoracic aorta just belo...
متن کاملEvaluation of blood products utilization in abdominal aortic aneurysm repair patients’ elective surgery in ShohadaTajrish Hospital
Abstract Background and Objectives Aortic aneurysm repair surgery (AAAs) is associated with massive bleeding that causes coagulation disorders during and after surgery. Considering that blood consumption in these patients has been studied in a few articles, we decided to investigate more. Materials and Methods In a cross-sectional study, patients with abdominal aortic aneurysms requiring surg...
متن کامل