Laboratory evaluation of 4 brands of endotracheal tube cuff inflator.
نویسنده
چکیده
INTRODUCTION Routine measurement of endotracheal tube (ETT) cuff pressure is a standard in respiratory care, and several devices are available for measuring ETT cuff pressure. Yet an informed choice in the buying process is hindered by the present paucity of unbiased, comparative data. METHODS Four brands of cuff inflator were tested: Posey Cufflator, DHD Cuff-Mate 2, Rüsch Endotest, and SIMS-Portex Cuff Pressure Indicator. Ten randomly selected 8.0-mm-inner-diameter ETTs were modified and tested in a trachea model. The cuffs were gradually inflated and deflated. After each sequential change in cuff volume, cuff pressure measurements were simultaneously recorded with the cuff inflator and with a calibration analyzer. These data were compared using limits-of-agreement analysis. Then, with each of the 10 ETTs, each cuff inflator was used to measure 3 known (ie, measured with the calibration analyzer) cuff pressures: 20, 40, and 60 cm H(2)O. Cuff pressure measurements were averaged, by brand, and compared to the respective baseline cuff pressure. Finally, using the 10 ETTs and trachea model, the ETT cuffs were inflated, in 0.25-mL increments, using only a syringe and the calibration analyzer. The cuff pressure and cuff volume data from that procedure were plotted and the best-fit regression line was determined. RESULTS There were differences in bias and precision among the tested cuff inflators. The Cuff-Mate 2 had the smallest bias and best precision. None of the cuff inflator brands accurately measured cuff pressure. In each case the Cuff-Mate 2 measured cuff pressures closest to actual. The Cuff-Mate 2 contains about half the compressible volume of that in the Endotest and Cufflator and < 20% of that in the Cuff Pressure Indicator. Regarding the relationship between cuff pressure and intracuff volume, the best-fit linear regression equation was: cuff volume = 0.05 x CP - 0.39 (r(2) = 0.96). CONCLUSIONS The 4 cuff inflators tested differ in bias and precision and none of the devices accurately measure cuff pressure. Cuff inflator manufacturers should design an accurate yet reasonably priced device to inflate ETT cuffs, and ideally that device should allow cuff-pressure checks without decreasing cuff pressure. In the meanwhile clinicians may opt to use my proposed cuff-pressure measurement technique, which minimizes the loss of cuff pressure during cuff-pressure checks and provides more accurate cuff-pressure measurements.
منابع مشابه
Decrease in cuff pressure during the measurement procedure: an experimental study
BACKGROUND To prevent endotracheal tube (ETT)-related complications during mechanical ventilation, ETT cuff pressure should be kept within proper range. In clinical settings, cuff pressure often decreases from target values. METHODS We performed an experimental study to investigate the effects of measuring devices and endotracheal tubes on change in cuff pressure. We continuously measured cuf...
متن کاملStudy of endotracheal tube cuff pressure and time of measurement among intensive care units patients
Introduction: The pressure in the endotracheal tube cuff must be kept within an optimal range, to make sure tracheal capillaries circulation still stable during positive ventilation. This is essential to avoid oral and gastric stuffing aspiration Objective: The objective of this study was to assess the endotracheal tube cuff pressure and time intervals measurements among intensive care units...
متن کاملAutomatic endotracheal tube cuff inflator and continuous pressure monitor/controller.
Endotracheal tube cuff pressure over 30 cm of water has been found to occur in about 50% of cases where cuff inflation was performed without monitoring, using pilot balloon palpation, minimal leak, or minimal occlusive volume techniques1. The incidence of post operative respiratory complications such as cough, sore throat, hoarseness, blood-streaked expectoration, and even tracheal stenosis is ...
متن کاملComparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level
Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...
متن کاملEffect of body position and head of bed angle on intra-abdominal and endotracheal tube cuff pressure in mechanically ventilated patients
Introduction: Changing position is one of the typical nursing care in intensive care units. This study aimed to investigate the effect of body positioning on intra-abdominal pressure and endotracheal tube cuff pressure and their relationship with each other in patients undergoing mechanical ventilation Materials and Methods: This was a before-after clinical trial study performed on 70 patients ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 49 2 شماره
صفحات -
تاریخ انتشار 2004