Drug-eluting stents in bifurcations: bench study of strut deformation and coating lesions.

نویسندگان

  • Patrice Guérin
  • Paul Pilet
  • Gérard Finet
  • Yann Gouëffic
  • Jean Michel N'Guyen
  • Dominique Crochet
  • Isabelle Tijou
  • Pierre Pacaud
  • Gervaise Loirand
چکیده

BACKGROUND The use of a drug-eluting stent (DES) has strongly limited the incidence of in-stent restenosis in bifurcation lesions; nevertheless, restenosis still remains a problem at the origin of the bifurcation side branch. The aim of this study is to analyze the consequences of the kissing postdilatation technique on 5 DESs, using microfocus x-ray computerized tomography and scanning electron microscopy. METHODS AND RESULTS Five different DESs (Cypher, Cypher Select, Endeavor, Taxus Express, and Taxus Liberté) were deployed using kissing postdilatation protocols in a bench-top model. For all types of DES, microfocus x-ray computerized tomography analysis showed that (1) kissing postdilatation of the stent by 2 coaxial balloons caused elliptic deformation in the proximal segment and (2) kissing postdilatation technique reduced the ratio of potential metal to artery (manufacturer's data/calculated ratio [%]: Cypher, 12.7/8.8; Cypher Select, 13.5/10.2; Endeavor, 19.0/13.3; Taxus Express, 20.5/4.7; Taxus Liberté, 17.9/12.5) and the potential drug application to area in the proximal segment, including the ostial struts (struts adjacent to and lying around the side branch ostium) (manufacturer's data/calculated drug application [microg/mm(2)]: Cypher, 1.4/1.0; Cypher Select, 1.4/1.1; Endeavor, 1.6/1.1; Taxus Express, 1.0/0.7; Taxus Liberté, 1.0/0.7). Scanning electron microscopy analysis showed a significantly greater coating damage to the ostial struts in all stents evaluated (P<0.05). CONCLUSIONS Commercially available DESs subjected to simultaneous kissing balloon postdilatation in an unconstrained model may contribute to side branch ostial restenosis by proximal segment elliptic deformation and damage to the polymer coating.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thin-strut drug-eluting stents are more favorable for severe calcified lesions after rotational atherectomy than thick-strut drug-eluting stents.

AIM Percutaneous coronary intervention (PCI) for severe calcified lesions is still challenging, and there are few studies of drug-eluting stent (DES) implantation for severe calcified lesions, especially regarding long-term results and hemodialysis patients. The study purpose was to clarify the factors, including DES strut thickness, that affect the long-term outcome of severe calcified lesion ...

متن کامل

Strut position, blood flow, and drug deposition: implications for single and overlapping drug-eluting stents.

BACKGROUND The intricacies of stent design, local pharmacology, tissue biology, and rheology preclude an intuitive understanding of drug distribution and deposition from drug-eluting stents (DES). METHODS AND RESULTS A coupled computational fluid dynamics and mass transfer model was applied to predict drug deposition for single and overlapping DES. Drug deposition appeared not only beneath re...

متن کامل

Implications for Single and Overlapping Drug-Eluting Stents

Background—The intricacies of stent design, local pharmacology, tissue biology, and rheology preclude an intuitive understanding of drug distribution and deposition from drug-eluting stents (DES). Methods and Results—A coupled computational fluid dynamics and mass transfer model was applied to predict drug deposition for single and overlapping DES. Drug deposition appeared not only beneath regi...

متن کامل

A stent is not just a stent: Stent construction and design do matter in its clinical performance.

The undisputed superiority of stents over conventional balloon angioplasty has resulted in a plethora of stents in clinical use. Recent data, however, have indicated not all stent models are the same. Nuances in stent design and construction have impacted significantly on the immediate and long-term clinical outcome. Among the stainless steel stents, those with multicellular or tubular designs ...

متن کامل

Strut coverage and vessel wall response to a new-generation paclitaxel-eluting stent with an ultrathin biodegradable abluminal polymer: Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI).

BACKGROUND Polymer-coated drug-eluting stents are effective in preventing restenosis but have been associated with delayed healing and incomplete strut coverage. It is unknown whether paclitaxel-eluting stents (PES) with minimal biodegradable abluminal coating enhances strut coverage while preventing neointimal hyperplasia. Using optical coherence tomography (OCT) as a primary imaging modality,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 3 2  شماره 

صفحات  -

تاریخ انتشار 2010