Assessment of volumetric absorbed dose for mobile fluoroscopic 3D image acquisition

نویسنده

  • Stephanie Leon
چکیده

Mobile fluoroscopy (c-arm) units offering 3D image reconstruction are becoming more common in surgical settings. Although these images are "CT-like" and sometimes replace the postoperative CT, the acquisition is technically very different from a traditional CT acquisition. Dose assessment is complicated by a large beam width, automatic exposure rate control, and a rotation of less than 360°. The purpose of this work was to explore the impact of these factors on the volumetric dose calculation and to provide practical recommendations for clinical physicists assessing dose from these units using commonly available equipment. CTDIW was calculated using the IAEA method for dosimetry of wide beams and compared to scans of the 32-cm CTDI phantom using the full beam width and a 20-mm collimated beam width. The impact of the partial rotation on the CTDIW calculation was assessed by acquiring measurements at four and twelve positions on the phantom periphery. For the system tested, the CTDIW was calculated to be 16.1 mGy using the IAEA method with default clinical protocol. Results showed that measuring CTDIW with the full beam width or a collimated beam width alone resulted in CTDI values of 19.0 mGy and 19.5 mGy, respectively. Using four peripheral measurements instead of 12 resulted in a difference of 4% for a collimated beam and 6% for an open beam. Variations in positioning on the order of a few centimeters resulted in a variation of only 4% with an open beam. The excellent reproducibility of the measurements using the full beam width suggests that this simple method is adequate for year-to-year comparisons. In contrast, the IAEA method is difficult to employ, particularly with 180° acquisitions. Use of peripheral measurements in excess of the usual four is time-consuming and not necessary for most applications obtained with the geometry specific to this system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient-bounded extrapolation using low-dose priors for volume-of-interest imaging in C-arm CT.

PURPOSE Three-dimensional (3D) volume-of-interest (VOI) imaging with C-arm systems provides anatomical information in a predefined 3D target region at a considerably low x-ray dose. However, VOI imaging involves laterally truncated projections from which conventional reconstruction algorithms generally yield images with severe truncation artifacts. Heuristic based extrapolation methods, e.g., w...

متن کامل

Patient-bounded Extrapolation for 3D Region of Interest Reconstruction in C-arm CT

Three-dimensional (3D) region of interest (ROI) imaging with C-arm systems provides anatomical information in a predefined 3D target region at a considerably low X-ray dose. A necessary initial step prior to a 3D acquisition is to isocenter the patient with respect to the target to be scanned. To this end, two low-dose fluoroscopic X-ray acquisitions are usually applied from anterior-posterior ...

متن کامل

A comparison of 2D and 3D kidney absorbed dose measures in patients receiving 177Lu-DOTATATE

Objective(s): To investigate and compare quantitative accuracy of kidney absorbed dose measures made from both 2D and 3D imaging in patients receiving 177LuDOTATATE (Lutate) for treatment of neuroendocrine tumours (NETs). Methods: Patients receiving Lutate therapy underwent both whole body planar imaging and SPECT/CT imaging over the kidneys at time points 0.5, 4, 24, and 96-120 hours after inj...

متن کامل

3D MRI gel dosimetry based on image intensity (A new approach)

Background: Since 1984 MRI gel dosimetry has been introduced as a potential technique for 3D dosimetry. Most of the studies have measured R1 (1/T1) or R2 (1/T2) properties of the gel depending on the gel type. We have studied image intensity change in the Fricke gel by different MRI protocols. Materials and Methods: Gel Dosimeters contain 0.4 mM ferrous sulphate, 1 mM NaCl, 50 mM H2SO4 and 1% b...

متن کامل

Evaluation of Volumetric Doses of Organs at Risk in Carcinoma Cervix Patients with HDR Intracavitary Brachytherapy and Comparison of CT-based and Conventional Plans

Background: Brachytherapy treatment planning in cervix carcinoma patients using two dimensional (2D) orthogonal images provides only point dose estimates while CT-based planning provides volumetric dose assessment helping in understanding the correlation between morbidity and the dose to organs at risk (OARs) and treatment volume. Objective: Aim of present study is to compare Internationa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017