Robust and Intuitive Meshing of Bone-Implant Compounds

نویسندگان

  • Max Kahnt
  • Francis Galloway
  • Heiko Seim
  • Hans Lamecker
  • Mark Taylor
  • Stefan Zachow
چکیده

To preoperatively assess the functional outcome of a total joint replacement, finite element analysis can be used for an objective evaluation of individual implant configurations. For large scale studies, where the implant configuration is varied in size, position or design, numerous finite element meshes have to be generated. To improve the planning process we propose a method that outputs a merged tetrahedral mesh of the patient’s joint anatomy and an arbitrarily positioned implant geometry suitable for finite element analysis. Our approach has several advantages: (1) it avoids error-prone intermediate stages, e.g. data type conversion, (2) it is able to preserve constraints such as sharp edges and (3) it can be fully automated by initially defining a few parameters that describe the desired geometric accuracy and element quality. Based on the meshing of 100 different patient-specific bone-implant setups at the tibia (shinbone), we show that our approach produces high-quality meshes in all cases automatically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود

Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...

متن کامل

تحلیل المان محدود ایمپلنت‌های دندانی در معرض بارگذاری حرارتی

  Background and Aims: Dental implants have been studied for replacement of missing teeth for many years. Productivity of implants is extremely related to the stability and resistance under applied loads and the minimum stress in jaw bone. The purpose of this study was to study numerically the 3D model of implant under thermal loads.   Materials and Methods: Bone and the ITI implant were modele...

متن کامل

Comparison of Implant Stability in Sinus Lift Surgery Using Autogenous Versus Allogeneic Bone Grafts

Background and aim: The most common method of increasing implant stability in the posterior maxilla comprises the reinforcement of bone height using bone grafts in sinus lift surgery. The purpose of the present study was to compare autogenous and allogeneic bone grafts in implant stability after open sinus lift surgery. Materials and methods: This split-mouth clinical trial compared the implant...

متن کامل

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011