Investigation of chimeric reads using the MinION

نویسندگان

  • Ruby White
  • Christophe Pellefigues
  • Franca Ronchese
  • Olivier Lamiable
  • David Eccles
چکیده

Following a nanopore sequencing run of PCR products of three amplicons less than 1kb, an abundance of reads failed quality control due to template/complement mismatch. A BLAST search demonstrated that some of the failed reads mapped to two different genes -- an unexpected observation, given that PCR was carried out separately for each amplicon. A further investigation was carried out specifically to search for chimeric reads, using separate barcodes for each amplicon and trying two different ligation methods prior to sample loading. Despite the separation of ligation products, chimeric reads formed from different amplicons were still observed in the base-called sequence.The long-read nature of nanopore sequencing presents an effective tool for the discovery and filtering of chimeric reads. We have found that at least 1.7% of reads prepared using the Nanopore LSK002 2D Ligation Kit include post-amplification chimeric elements. This finding has potential implications for other amplicon sequencing technologies, as the process is unlikely to be specific to the sample preparation used for nanopore sequencing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of chimeric reads using the MinION

Following a nanopore sequencing run of PCR products of three amplicons less than 1kb, an abundance of reads failed quality control due to template/complement mismatch. A BLAST search demonstrated that some of the failed reads mapped to two different genes -an unexpected observation, given that PCR was carried out separately for each amplicon. A further investigation was carried out specifically...

متن کامل

MinION Analysis and Reference Consortium: Phase 2 data

Background: Long-read sequencing is rapidly evolving and reshaping the suite of opportunities for genomic analysis. For the MinION in particular, as both the platform and chemistry develop, the user community requires reference data to set performance expectations and maximally exploit third-generation sequencing. We performed an analysis of MinION data derived from whole genome sequencing of K...

متن کامل

The long reads ahead: de novo genome assembly using the MinION

Nanopore technology provides a novel approach to DNA sequencing that yields long, label-free reads of constant quality. The first commercial implementation of this approach, the MinION, has shown promise in various sequencing applications. This review gives an up-to-date overview of the MinION's utility as a de novo sequencing device. It is argued that the MinION may allow for portable and affo...

متن کامل

A sequencer coming of age: de novo genome assembly using MinION reads

Nanopore technology provides a novel approach to DNA sequencing that yields long, label-free reads of constant quality. The first commercial implementation of this approach, the MinION, has shown promise in various sequencing applications. The presented literature review gives an up-to-date overview of the MinION’s utility as a de novo sequencing device. It is argued that the MinION may allow f...

متن کامل

Scaffolding of a bacterial genome using MinION nanopore sequencing

Second generation sequencing has revolutionized genomic studies. However, most genomes contain repeated DNA elements that are longer than the read lengths achievable with typical sequencers, so the genomic order of several generated contigs cannot be easily resolved. A new generation of sequencers offering substantially longer reads is emerging, notably the Pacific Biosciences (PacBio) RS II sy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017