Open and closed-circuit endotracheal suctioning in acute lung injury: efficiency and effects on gas exchange.

نویسندگان

  • Sigismond Lasocki
  • Qin Lu
  • Alfonso Sartorius
  • Dominique Fouillat
  • Francis Remerand
  • Jean-Jacques Rouby
چکیده

BACKGROUND Closed-circuit endotracheal suctioning (CES) is advocated for preventing hypoxemia caused by the loss of lung volume resulting from open endotracheal suctioning (OES). However, the efficiency of CES and OES on tracheal secretion removal has never been compared in patients with acute lung injury. The authors designed a two-part study aimed at comparing gas exchange and efficiency between OES and CES performed at two levels of negative pressure. METHODS Among 18 patients with acute lung injury, 9 underwent CES and OES at 3-h intervals in a random order using a negative pressure of -200 mmHg. Nine other patients underwent CES twice using two levels of negative pressure (-200 and -400 mmHg) applied in a random order. After each CES, a recruitment maneuver was performed using 20 consecutive hyperinflations. Tracheal aspirates were weighed after each suctioning procedure. Arterial blood gases were continuously recorded using an intravascular sensor. RESULTS Open endotracheal suctioning induced a significant 18% decrease in arterial oxygen tension (Pa(O2)) (range, +13 to -71%) and an 8% increase in arterial carbon dioxide tension (Pa(CO2)) (range, -2 to +16%) that persisted 15 min after the end of the procedure. CES using -200 cm H2O did not change Pa(O2), but tracheal aspirate mass was lower compared with OES (0.6 +/- 1.0 vs. 3.2 +/- 5.1 g; P = 0.03). Increasing negative pressure to -400 cm H2O during CES did not change Pa(O2) but increased the tracheal aspirate mass (1.7 +/- 1.6 vs. 1.0 +/- 1.3 g; P = 0.02). CONCLUSIONS Closed-circuit endotracheal suctioning followed by a recruitment maneuver prevents hypoxemia resulting from OES but decreases secretion removal. Increasing suctioning pressure enhances suctioning efficiency without impairing gas exchange.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of the effect of open and closed endotracheal suctioning on hemodynamic status of patients in the ICU

Background: If not done properly, suction causes complications such as hypoxia, cardiac arrhythmias or even death. Suction is being used in most hospital wards. Closed Suction appears to have fewer side effects, although studies have reported dissimilar results. Aim: The aim of this study was to compare the effect of open (control) with closed (test) endotracheal suctioning on patients’ Hemodyn...

متن کامل

Differential Effects of Endotracheal Suctioning on Gas Exchanges in Patients with Acute Respiratory Failure under Pressure-Controlled and Volume-Controlled Ventilation

This study was conducted to evaluate the effects of open endotracheal suctioning on gas exchange and respiratory mechanics in ARF patients under the modes of PCV or VCV. Ninety-six ARF patients were treated with open endotracheal suctioning and their variations in respiratory mechanics and gas exchange after the suctions were compared. Under PCV mode, compared with the initial level of tidal vo...

متن کامل

Bench-to-bedside review: Adjuncts to mechanical ventilation in patients with acute lung injury

Mechanical ventilation is indispensable for the survival of patients with acute lung injury and acute respiratory distress syndrome. However, excessive tidal volumes and inadequate lung recruitment may contribute to mortality by causing ventilator-induced lung injury. This bench-to-bedside review presents the scientific rationale for using adjuncts to mechanical ventilation aimed at optimizing ...

متن کامل

Repeated open endotracheal suctioning causes gradual desaturation but does not exacerbate lung injury compared to closed endotracheal suctioning in a rabbit model of ARDS

BACKGROUND Although endotracheal suctioning induces alveolar derecruitment during mechanical ventilation, it is not clear whether repeated endotracheal suctioning exacerbates lung injuries. The present study aimed to determine whether repeated open endotracheal suctioning (OS) exacerbates lung injury compared to closed endotracheal suctioning (CS) during mechanical ventilation in an animal mode...

متن کامل

تأثیر ساکشن به دو روش سیستم باز و بسته بر علایم حیاتی بیماران بستری در بخش مراقبت‌های ویژه

Background & Aim: Nowadays, mechanical ventilators are being used for some patients in ICUs due to various physiological and clinical causes. Keeping endotracheal tube clean and open is necessary in order to improve the patient;aposs oxygenation. This study aimed to investigate the effects of open and closed system endotracheal suctioning on vital signs of patients in ICU. Methods & Materials:...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 104 1  شماره 

صفحات  -

تاریخ انتشار 2006