Rapid technique for imaging the blood vascular system using stereoangiography.

نویسندگان

  • Jayc C Sedlmayr
  • Lawrence M Witmer
چکیده

Data on vascular anatomy traditionally have been derived from time-consuming gross dissection and histology, which has prevented the assembly of large sample sizes. Vascular injection of radiopaque medium (angiography) is a rapid technique, but, as typically performed, it has limitations (e.g., superimposition and poor subsequent dissectibility). We present a novel angiographic technique comprised of two elements: 1) a new, dissectible injection medium; and (2) stereoradiography. The injection medium consists of liquid barium (providing radiopacity) and latex (providing dissectibility). Domestic duck heads were the study system. The relative concentrations of barium and latex were varied, and the resulting radiographs were assayed for vessel radiopacity and the number of observable vessels. A wide range of barium percentages yielded excellent results, suggesting that preparation of the medium can be "eyeballed" for most applications, which enhances processing speed. The stereoradiographic element solved the superimposition problem, allowing stunning resolution of the spatial relationships of vessels to each other and to other tissues. Stereoangiography is a fast and easy technique that permits the acquisition of detailed anatomical data from many specimens, thereby enabling something rarely achieved: population-level anatomical studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of using Medical Imaging Interaction Toolkit in volumetric studies to accurate diagnosing of vascular emboli by Extended NURBS-based Cardiac-Torso phantom

Introduction: Important complications of venous thromboembolism (VTE) are a longer hospital stay, readmission, recurrence of the emboli, complications of anticoagulant therapy and death in a sever condition. In present study, the volume measurement accuracy of the medical imaging interaction toolkit (MITK) software on determining VTE in computed tomography images was evaluated....

متن کامل

Real-time optoacoustic monitoring of vascular damage during photodynamic therapy treatment of tumor.

The optoacoustic technique is a noninvasive imaging method with high spatial resolution. It potentially can be used to monitor anatomical and physiological changes. Photodynamic therapy (PDT)-induced vascular damage is one of the important mechanisms of tumor destruction, and real-time monitoring of vascular changes can have therapeutic significance. A unique optoacoustic system is developed fo...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Anatomical record

دوره 267 4  شماره 

صفحات  -

تاریخ انتشار 2002