Laser-induced breakdown spectroscopy in analysis of Al3+ liquid droplets: on-line preconcentration by use of flow-injection manifold.
نویسندگان
چکیده
Laser-induced breakdown spectroscopy (LIBS), combined with a flow-injection system, is demonstrated to analyze liquid droplets of aluminum salt, as generated with an electrospray ionization device. The spray needle also serves as the anode, through which the analyte solution is spread toward the other metal base as the cathode. Along the passage of the FI manifold, the Al-sample loading speed is controlled at 0.15 mL min(-1), restricted to the small diameter of the spray needle, and the loading volume amounts to 0.1 mL. The metal ion is retained in a cation-exchange resin microcolumn immobilized with Chromotrope 2B chelating agent, followed by elution with a 0.5 M HCl solution into LIBS. Upon laser irradiation at the preconcentrated liquid droplets, the time-resolved laser-induced breakdown (LIB) emission and plasma-induced current signals are acquired concurrently on a single-shot basis. The area under the LIB/current distribution increases in linear proportion as the concentration of the sample solution increases. The detection limit thus obtained can reach 1.5 mg L(-1), about an order of magnitude lower than those achieved previously using single-laser ablation without involvement of preconcentration. The linear dynamic range is more than two orders of magnitude.
منابع مشابه
The effect of self-absorption correction using internal reference on determining heavy metals concentration by laser induced breakdown spectroscopy
The identification and concentration of heavy metals, which may be so harmful for the body, is determined by the method of calibration-free laser-induced breakdown spectroscopy using a special strategy. First, the plasma temperature is obtained using the Boltzmann plot. Then, a line with an inappreciable self-absorption is considered for each element as the reference. The modified intensities o...
متن کاملSorption of platinum on immobilized microorganisms for its on-line preconcentration and chemiluminescent determination in water samples
Fungi of the type Aspergillus sp. were immobilized on a cellulosic resin and used as a biosorbent for the on-line preconcentration and separation of Pt(IV) ions prior to their chemiluminescent determination via flow injection analysis. Biosorption and elution conditions were optimized, and the results compared to biosorbents based on the use of Chlorella vulgaris algae and Saccharomyces cerevis...
متن کاملLaser-Induced Breakdown and Detonation in Particle-Laden Systems
Article history Received: 18-08-2014 Revised: 19-11-2014 Accepted: 26-01-2015 Abstract: Simulation of the interaction of a laser pulse with gas-droplet and gas-particle mixtures plays an important role in environmental and engineering applications. The injection of liquid droplets or metal particle causes optical breakdown on the individual droplet or particle and leads to a drop of the detonat...
متن کاملThe Effects of Pressure Difference in Nozzle’s two Phase Flow on the Quality of Exhaust Mixture
In the most application of nozzle with gas-liquid two-phase flow, the quality of mixture in exhaust of nozzle is the most important parameter as well as the flow velocity. On the other hand, in some industrial application, such as water injection in forced induction (turbocharged or supercharged) internal combustion engine the spray quality is the main goal of designing. In this case and for im...
متن کاملComparison of traditional cloud-point extraction and on-line flow-injection cloud-point extraction with a chemiluminescence method using benzo[a]pyrene as a marker.
In this work, using benzo(a)pyrene (BaP) as marker, the analytical merits of on-line flow-injection cloud-point extraction (FI CPE), including preconcentration factor, extraction efficiency, sample throughput, and analysis time were evaluated by use of peroxyoxalate chemiluminescence (CL) detection. Moreover, by detailed discussion of several preconcentration conditions for traditional and on-l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytica chimica acta
دوره 581 2 شماره
صفحات -
تاریخ انتشار 2007