Maximum blood flow and microvascular regulatory responses in systemic sclerosis.

نویسندگان

  • H Gunawardena
  • N D Harris
  • C Carmichael
  • N J McHugh
چکیده

Objectives. To investigate microvascular function using laser Doppler imaging (LDI) following response to hyperaemia, neurovascular reflex and iontophoresis in systemic sclerosis (SSc) in comparison with primary Raynaud's phenomenon (PRP) and age-matched controls. A secondary aim was to evaluate if SSc patients with a higher Medsger vascular score have lower endothelial responses. Methods. Twenty patients with SSc, 10 PRP and 17 controls were studied. Patients with SSc were scored using the vascular component of the Medsger severity scale. A baseline LDI scan was performed on the dorsal aspect of both hands. Digital responses were quantified following maximum hyperaemic response (MHR), contralateral vasoconstrictor response (CLVc) and iontophoresis with acetylcholine (Ach)-endothelial dependent and sodium nitroprusside (SNP)-endothelial independent. Mean blood flow was quantified over a standard region of interest. Results. MHR was lower in SSc patients compared with controls (P < 0.001). A similar trend was seen when comparing SSc with PRP although this did not reach significance (P = 0.07). CLVc and Ach/MHR were lower in SSc vs PRP (P < 0.05) and controls (P < 0.001). No difference was observed in MHR, CLVc and Ach/MHR between PRP and controls. Overall, SNP/MHR was similar in all the three groups. SSc patients with a higher Medsger vascular score had lower endothelial-dependent (P < 0.01) and independent (P < 0.05) responses. Conclusion. SSc patients have abnormal microvascular regulatory responses compared with PRP and controls. This study also suggests that the degree of endothelial dysfunction may be related to the degree of peripheral vascular involvement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Nailfold capillaroscopy and blood flow laser-doppler analysis of the microvascular damage in systemic sclerosis: preliminary results].

OBJECTIVES Systemic sclerosis (SSc) is characterized by altered microvascular structure and function. Nailfold videocapillaroscopy (NVC) is the tool to evaluate capillary morphological structure and laser-Doppler Blood flowmetry (LDF) can be used to estimate cutaneous blood flow of microvessels. The aim of this study was to investigate possible relationships between capillary morphology and blo...

متن کامل

Numerical status of CD4+CD25+FoxP3+ and CD8+CD28- regulatory T cells in multiple sclerosis

Objective(s): Regulatory T cells, including CD4+CD25+Fox3+ and CD8+CD28- cells play an important role in regulating the balance between immunity and tolerance. Since multiple sclerosis is an inflammatory autoimmune disease, regulatory T cells are considered to be involved in its pathogenesis. In this study, we investigated the circulatory numbers of the two mentioned types of regulatory T cells...

متن کامل

Methods for the morphological and functional evaluation of microvascular damage in systemic sclerosis

Systemic sclerosis is a connective tissue disease characterized by alterations in microvascular structure and function. In these patients, numerous studies have demonstrated a relationship between capillary morphology and peripheral blood perfusion. Nailfold videocapillaroscopy reveals the peripheral microvascular morphology and thus allows classification and scoring of capillary abnormalities ...

متن کامل

Digital vascular response to topical glyceryl trinitrate, as measured by laser Doppler imaging, in primary Raynaud's phenomenon and systemic sclerosis.

OBJECTIVE To investigate digital microvascular responses to topical glyceryl trinitrate (GTN) in patients with primary Raynaud's phenomenon (PRP), limited cutaneous systemic sclerosis (LCSSc) and healthy control subjects, using laser Doppler imaging. METHODS Ten patients with PRP, 13 with LCSSc and 10 control subjects were studied. Baseline skin microvascular blood flow of the dorsum of the i...

متن کامل

A time-response model for analysis of drug transport and blood flow response during iontophoresis of acetylcholine and sodium nitroprusside.

BACKGROUND/AIMS The analysis of blood flow responses to iontophoresis of vasoactive drugs is often limited to evaluation of maximum responses. In this study, a time-response model is proposed for the blood flow responses to vasoactive drugs applied by iontophoresis. METHODS The microvascular bed is represented as a single compartment with a zero-order influx of the drugs from the electrode an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rheumatology

دوره 46 7  شماره 

صفحات  -

تاریخ انتشار 2007