The Use of Series Compliance and Variable Transmission Elements in the Design of a Powered Knee Prosthesis

نویسندگان

  • Matthewson Mooney
  • Luke Matthewson Mooney
چکیده

Compared to non-amputees, above knee amputees expend significantly more metabolic energy. This is a result of the passive nature of most knee prostheses, as the development of clinically successful powered knee prostheses has remained a challenge. The addition of powered elements, such as electric motors, allow prosthetic knees to more closely emulate natural knee biomechanics. However, the addition of powered elements presents a new challenge of creating energy efficient devices that do not require frequent charging or excessively large batteries. In this thesis, a general optimization routine was developed to simulate and evaluate the electrical economy of various actuator architectures. Advanced actuators utilizing variable transmissions with elastic elements were compared to direct drive actuators, series elastic actuators, and two novel mechanisms known as the continuously-variable series-elastic actuator (CV-SEA) and the clutchable series-elastic actuator (CSEA). The CV-SEA is similar to a traditional series-elastic actuator (SEA), but uses a controllable continuouslyvariable transmission (CVT) in between the series-elastic element and the motor. The CSEA included a low-power clutch in parallel with an electric motor within a traditional series-elastic actuator. The stiffness of the series elasticity was tuned to match the elastically conservative region of the knees torque-angle relationship during early stance phase knee flexion and extension. During this region of the gait cycle, the clutch was engaged and elastic energy was stored in the spring, thereby providing the reactionary torque at a substantially reduced electrical cost. The optimization routine showed that the electrical economy of knee prostheses can be greatly improved by implementing variable transmissions in series with elastic elements. The optimization routine also estimated that a CSEA knee prosthesis could provide an 83% reduction in electrical cost, when compared to an SEA knee prosthesis. Although the variable transmission actuators were predicted to be more electrically economical than the CSEA knee, their design complexity limits their current feasibility in a knee prosthesis. Thus, a fully autonomous knee prosthesis utilizing the CSEA was designed, developed and tested. The CSEA Knee was actuated with a brushless electric motor; ballscrew transmission and cable drive as well as commercial electrical components.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive Controller Design for Swing Phase of a Single Axis Above-Knee Prosthesis

In this research we design a passive controller for an above knee prosthesis. The controller is a linear spring and damper for swing phase motion, parameters of which determined via optimization of adjustment of the prosthesis shank motion with a desired shank angle trajectory comes from experimental data. In this way, we exerted a certain thigh motion, hip movement included, into the system as...

متن کامل

Dynamics of a Running Below-Knee Prosthesis Compared to Those of a Normal Subject

The normal human running has been simulated by two-dimensional biped model with 7 segments. Series of normal running experiments were performed and data of ground reaction forces measured by force plate was analyzed and was fitted to some Fourier series. The model is capable to simulate running for different ages and weights at different running speeds. A proportional derivative control algorit...

متن کامل

Design Evaluation in Novel Orthoses for Patients with Medial Knee Osteoarthritis

Osteoarthritis of the knee is a debilitating condition affecting increasing numbers of individuals each year. One option for treatment is orthotic knee braces, but a little independent reviews have taken place to date on their relative outcomes for users. This study therefore evaluates the efficacy of different types of knee orthoses (braces) with regard to key aspects of use, including gait pa...

متن کامل

Impact of Powered Knee-Ankle Prosthesis on Low Back Muscle Mechanics in Transfemoral Amputees: A Case Series

Regular use of prostheses is critical for individuals with lower limb amputations to achieve everyday mobility, maintain physical and physiological health, and achieve a better quality of life. Use of prostheses is influenced by numerous factors, with prosthetic design playing a critical role in facilitating mobility for an amputee. Thus, prostheses design can either promote biomechanically eff...

متن کامل

Optimization of Ankle-Foot Prosthesis with Active Alignment by Passive Elements

Today, often ankle’s active prosthesis is used for transtibial amputated people’s walking, because these prostheses have some advantages such as increasing power and decreasing metabolism. In most of active prosthesis in order to create a movement or increase the force at the push-off, electrical actuators are used like a motor. In cases where a higher-power motor is necessary, the capacity, we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014