Transportation Assessment in Simulated Curved Canals after preparation with Twisted File Adaptive and BT-Race instruments
نویسندگان
چکیده
BACKGROUND This study compared the incidence of deviation along curved canals after preparation with two nickel-titanium (NiTi) rotary systems, Twisted File Adaptive and BT-RaCe. MATERIAL AND METHODS Forty resin training blocks with curved canals were filled with ink and divided into two groups according to the instrumentation technique. Preinstrumentation images were acquired by using a stereomicroscope. The canals were up to an instrument #35/0.04. Postinstrumentation images were captured using the same conditions, and the images were superimposed. The amount of resin removed was measured at 8 different points, beginning at the apical terminus of the canal. Differences in the mesial and distal aspects were measured to evaluate the occurrence of deviation. The Student's-t test was used for comparison of the intragroup deviation. Intergroup analysis was performed by using one-way ANOVA for each level. For multiple comparisons, the Bonferroni test was used and a cutoff for significance was set at 5%. RESULTS Intragroup analysis showed that both instrumentation techniques promoted some deviation at all levels. BT-RaCe showed significantly lower deviation at 0 and 4-mm levels than Group Twisted File Adaptive (p<0.05). On the other hand BT-RaCe showed worse performance at level 6. CONCLUSIONS The results of this study demonstrated that none of the NiTi tested systems was able to instrument curved canals simulated in resin blocks without some deviation during the preparation. There is still need for improvement in the instruments manufacturing aiming the better performance of endodontic files in curved root canals. Key words:BT-RaCe, Curved root canals, Deviation, Twisted File Adaptive.
منابع مشابه
Comparison of the maintenance of root canal anatomy in severely curved resin blocks using RaCe and Flexmaster rotary systems
Comparison of the maintenance of root canal anatomy in severely curved resin blocks using RaCe and Flexmaster rotary systems Dr. S. Khedmat* - Dr. M. Vahdatifar** *- Associate Professor of Endodontics Dept. - Faculty of Dentistry – Tehran University of Medical Sciences. **- Endodontist. Background and Aim: Various rotary systems are available on the market, therefore selection of a proper instr...
متن کاملAn Ex vivo Analysis of Apical Transportation in Root Canals Prepared with BT Race Rotary and Hand K-Flexofile by Cone Beam Computed Tomography
Background and purpose: The purpose of mechanical cleaning of the root canal is to clean the canal walls, create a conical shape to facilitate access, effective washing, and filling all areas of the root canal. Errors such as root canal transportation are cuased by excessive dentin removal from the canal. The objective of this study was to investigate root canal transportation by a BT Race rota...
متن کاملEvaluation of Root Canal Transportation using Bio Race and K -Flexo file instruments: using cone-Bean Computed
Background & Aim: Deviation from the original shape of the canal leads to poor filling and lack of proper canal seal and consequently to the failure of root treatment The aim of this experimental study was to determine the extent of apical transportation after instrumentation with hand K-Flexofile and BioRace rotary instruments by cone-beam computed tomography (CBCT). Material and Methods: In t...
متن کاملمقایسه آمادهسازی کانال ریشه با استفاده از فایلهای نیکل تیتانیومی دستی و روتاری Race
Introduction: Successful treatment of root depends on complete elimination of debris and bacteria’s from root canal system and appropriate shaping of canal in obturation canal preparation is the most difficult and time consuming stage during root canal treatment. This stage especially in curved and narrow canals always causes some problems for students, general dentist and specialist. Following...
متن کاملShaping ability of ProTaper NEXT and BT-RaCe nickel-titanium instruments in severely curved root canals.
AIM To compare the shaping ability of four different nickel-titanium rotary instruments during the preparation of curved root canals in extracted teeth. METHODOLOGY A total of 80 root canals with curvatures ranging between 25° and 39° were divided into four groups of 20 canals. Based on radiographs taken prior to instrumentation, the groups were balanced with respect to the angle and the radi...
متن کامل