Outcome of Transcatheter Closure of Oval Shaped Atrial Septal Defect with Amplatzer Septal Occluder

نویسندگان

  • Jinyoung Song
  • Sang Yoon Lee
  • Jae Sook Baek
  • Woo Seub Shim
  • Eun Young Choi
چکیده

PURPOSE For the successful completion of transcatheter closure of atrial septal defects with the Amplatzer septal occluder, shape of the defects should be considered prior to selecting the device. The purpose of this study is to evaluate the results of a transcatheter closure of oval shaped atrial septal defect. MATERIALS AND METHODS From November 2009 until November 2011, cardiac computed tomography was performed on 69 patients who needed a transcatheter closure of atrial septal defect. We defined an oval shaped atrial septal defect as the ratio of the shortest diameter to the longest diameter ≤ 0.75 measured using computed tomography. A trans-thoracic echocardiogram was performed one day after and six months after. RESULTS The transcatheter closure of atrial septal defect was performed successfully in 24 patients in the ovoid group and 45 patients in the circular group. There were no serious complications in both groups and the complete closure rate at 6 months later was 92.3% in the ovoid group and 93.1% in the circular group (p>0.05). The differences between the device size to the longest diameter of the defect and the ratios of the device size to the longest diameter were significantly smaller in the ovoid group (1.8 ± 2.8 vs. 3.7 ± 2.6 and 1.1 ± 0.1 vs. 1.2 ± 0.2). CONCLUSION Transcatheter closure of an oval shaped atrial septal defect was found to be safe with the smaller Amplatzer septal occluder device when compared with circular atrial septal defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the geometric profile of the Amplatzer and Cardioseal septal occluders by three dimensional echocardiography.

OBJECTIVE To apply three dimensional echocardiography to describe the geometric profile of the Amplatzer and Cardioseal occluders after deployment for closure of atrial septal defect. METHODS 20 patients (mean (SD) age, 14 (5) years) were enrolled for transcatheter closure of a secundum atrial septal defect with the Amplatzer occluder (10) or with the Cardioseal occluder (10). The two populat...

متن کامل

Congenital Heart Disease Transcatheter Closure of Atrial Septal Defects with the Amplatzer Septal Occluder Clinical Results

Objective: To assess the short-term outcome following transcatheter closure of secundum atrial septal defect (ASD) in our hospital. Patients and Methods: Between June 2000 and November 2001, 20 patients diagnosed as secundum atrial septal defects underwent transcatheter closure of their defects using the Amplatzer septal occluder (ASO) device. Indications for 18 patients were larger atrial sept...

متن کامل

Amplatzer septal occluder-induced transient complete atrioventricular block.

Percutaneous transcatheter atrial septal defect (ASD) closure is a widely used technique that has replaced open-heart surgical closure in many centers. The most common implant is the Amplatzer septal occluder which seems to be a highly effective and safe device. However, there are reports of complications associated with its implantation. We report a 9-year-old boy who presented with complete a...

متن کامل

[Transcatheter closure of postinfarction ventricular septal defects using Amplatzer devices].

We carried out transcatheter procedures to close postinfarction ventricular septal defects (PIVSDs) in 19 patients: two had recanalization after surgical closure, and 17 had a primary PIVSD. In three of the latter patients, who had acute PIVSDs, the procedure was carried out in the first 3 weeks after infarction; in the 13 patients with subacute PIVSD, it was carried out 3.5-12 weeks after infa...

متن کامل

Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders.

OBJECTIVES The aim of this study was to assess long-term results of percutaneous closure of secundum-type atrial septal defect (ASD II) using Amplatzer septal occluders (ASO). BACKGROUND Only immediate-, short-, and intermediate-term results of ASO implantation are known so far. METHODS Between September 1995 and January 2000, 151 patients underwent a successful percutaneous closure of ASD ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2013