Dosimetric evaluation of nasopharyngeal carcinomas irradiated with different IMRT techniques.

نویسندگان

  • Sevim Ozdemir
  • Yasin Coban
  • Mustafa Akin
  • Pinar Ambarcioglu
  • Ozgehan Onay
  • Cumhur Yildirim
  • Esengul Uzel
  • Omer Uzel
چکیده

PURPOSE To evaluate the performance of volumetric arc therapy (VMAT), dynamic intensity modulated radiotherapy (IMRT) and step-and-shoot IMRT techniques in nasopharyngeal cancer (NPC) patients. METHODS IMRT plans of 48 NPC patients treated between May 2010 and December 2012, were evaluated. Twenty two patients were planned with VMAT, 18 with dynamic IMRT and 8 with step-and-shoot IMRT. Conformity index (CI) and homogeneity index (HI), the dosimetry of the planning target volumes (PTVs) and organs at risk (OARs) and the monitor units (MU) were evaluated for each IMRT modality. RESULTS The conformity indices of VMAT and dynamic IMRT were better than step-and-shoot IMRT plans (p<0.05). Step-and-shoot IMRT plans provided better homogeneity than VMAT (p=0.01). MUs for dynamic IMRT were much higher compared to VMAT (p<0.01) and step and- shoot IMRT (p<0.01). There was no significant difference between the 3 techniques in terms of PTV70 mean doses. When compared with step-and-shoot IMRT, VMAT and dynamic IMRT had a better sparing effect on optic nerves, eyes and optic chiasm (p<0.05). VMAT plans performed better sparing for brain stem than dynamic IMRT (p=0.01). There was a remarkable decrease in the maximum doses of VMAT to the eye. CONCLUSIONS VMAT outperforms dynamic IMRT by effectively reducing the MU and the dose to some OARs, with adequate PTV coverage. Also, VMAT provides better sparing of normal tissue and conformity than step-and-shoot IMRT. Differences between step-and-shoot IMRT and dynamic IMRT are thought to be due to technical differences of linear accelerator devices like fiber size, variable fiber, dose rate and gantry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric verification for primary focal hypermetabolism of nasopharyngeal carcinoma patients treated with dynamic intensity-modulated radiation therapy.

OBJECTIVE To make sure the feasibility with (18F)FDG PET/CT to guided dynamic intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma patients, by dosimetric verification before treatment. METHODS Chose 11 patients in III~IVA nasopharyngeal carcinoma treated with functional image-guided IMRT and absolute and relative dosimetric verification by Varian 23EX LA, ionization cham...

متن کامل

Dosimetric benefits of placing dose constraints on the brachial plexus in patients with nasopharyngeal carcinoma receiving intensity-modulated radiation therapy: a comparative study

This study aimed to evaluate whether placing dose constraints on the brachial plexus (BP) could provide dosimetric benefits in patients with nasopharyngeal carcinoma (NPC) undergoing intensity-modulated radiation therapy (IMRT). Planning CT images for 30 patients with NPC treated with definitive IMRT were retrospectively reviewed. Target volumes, the BP and other critical structures were deline...

متن کامل

Dosimetric impact of using the Acuros XB algorithm for intensity modulated radiation therapy and RapidArc planning in nasopharyngeal carcinomas.

PURPOSE To assess the dosimetric implications for the intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy with RapidArc (RA) of nasopharyngeal carcinomas (NPC) due to the use of the Acuros XB (AXB) algorithm versus the anisotropic analytical algorithm (AAA). METHODS AND MATERIALS Nine-field sliding window IMRT and triple-arc RA plans produced for 12 patients with...

متن کامل

Clustering of nasopharyngeal carcinoma intensity modulated radiation therapy plans based on k-means algorithm and geometrical features

Background: The design of intensity modulated radiation therapy (IMRT) plans is difficult and time-consuming. The retrieval of similar IMRT plans from the IMRT plan dataset can effectively improve the quality and efficiency of IMRT plans and automate the design of IMRT planning. However, the large IMRT plans datasets will bring inefficient retrieval result. Materials and Methods: An intensity-m...

متن کامل

Evaluation of the effects of dental filling material artifacts on IMRT treatment planning in patient with nasopharyngeal cancer

Background: Presence of artifacts, caused by dental filling high-Z materials (DFM), on intensity-modulated radiation therapy (IMRT) treatment plan CT images may lead to uncertainty in head and neck calculated dose distributions. Hence, the purpose of this study was to investigate the effects of DFM on the IMRT calculated dose distribution and consequent radiobiological derived outcomes for naso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of B.U.ON. : official journal of the Balkan Union of Oncology

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 2014