Calculation of intraocular lens power using Orbscan II quantitative area topography after corneal refractive surgery.

نویسندگان

  • Carlos G Arce
  • Eduardo S Soriano
  • Robert W Weisenthal
  • Stephen M Hamilton
  • Karolinne M Rocha
  • Juan B Alzamora
  • Eduardo J Maidana
  • Vijayalakshmi L Vadrevu
  • Kenneth Himmel
  • Paulo Schor
  • Mauro Campos
چکیده

PURPOSE To present the prospective application of the Orbscan II central 2-mm total-mean corneal power obtained by quantitative area topography in intraocular lens (IOL) calculation after refractive surgery. METHODS Calculated and achieved refraction and the difference between them were studied in 77 eyes of 61 patients with previous radial keratotomy (RK), RK and additional surgeries, myopic LASIK, myopic photorefractive keratectomy (PRK), or hyperopic LASIK who underwent phacoemulsification without complications in 3 eye centers. All IOL calculations used the average from the central 2-mm Orbscan II total-mean power of maps centered on the pupil without the use of previous refractive data. Six IOL styles implanted within the bag were used. RESULTS Using the SRK-T formula, the overall calculated refraction was -0.64+/-0.93 diopters (D). The overall achieved spherical equivalent refraction (-0.52+/-0.79 D; range: -3.12 to 1.25 D; 95% confidence interval [CI]: -0.70/-0.34 D) was +/-0.50 D in 53% of eyes, +/-1.00 D in 78% of eyes, and +/-2.00 D in 99% of eyes. The overall difference between the calculated and achieved refraction (0.12+/-0.93 D, P=.27; range: -2.18 to 2.62 D; 95% CI: 0.09/0.33 D) was +/-0.50 D in 39% of eyes, +/-1.00 D in 77% of eyes, and +/-2.00 D in 96% of eyes. This difference was +/-1.00 D in 77% of eyes with RK (P=.70), 82% of eyes with myopic LASIK (P=.34), and 90% of eyes with myopic PRK (P=.96). In eyes with RK followed by LASIK, a trend toward undercorrection was noted (P=.03). In eyes with hyperopic LASIK, a trend toward overcorrection was noted (P=.005). CONCLUSIONS In eyes with previous corneal refractive surgery, IOL power calculation can be performed with reasonable accuracy using the Orbscan II central 2-mm total-mean power. This method had better outcomes in eyes with previous RK, myopic LASIK, and myopic PRK than in eyes with hyperopic LASIK or RK with LASIK.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Orbscan II-assisted intraocular lens power calculation for cataract surgery following myopic laser in situ keratomileusis (an American Ophthalmological Society thesis).

PURPOSE This study tests the hypothesis that the keratometric value derived from Orbscan II mean power maps, when used in an intraocular lens (IOL) calculation formula, at a specific measurement zone, will accurately determine the power of an IOL for planned cataract surgery in patients who have undergone prior myopic laser-assisted in situ keratomileusis (LASIK). METHODS This is a two-part s...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

Anterior Elevation Maps as the Screening Test for the Ablation Power of Previous Myopic Refractive Surgery

PURPOSE We classified the Orbscan anterior elevation maps in normal eyes (under myopic, emmetropic and hyperopic conditions) and in those after myopic refractive surgery. We did this classification to demonstrate how Orbscan anterior elevation maps are useful in screening for the existence and extent of previous myopic refractive surgery. Such a classification can help clinicians interpret preo...

متن کامل

Personalized Pseudophakic Model for Refractive Assessment

PURPOSE To test a pseudophakic eye model that allows for intraocular lens power (IOL) calculation, both in normal eyes and in extreme conditions, such as post-LASIK. METHODS PARTICIPANTS The model's efficacy was tested in 54 participants (104 eyes) who underwent LASIK and were assessed before and after surgery, thus allowing to test the same method in the same eye after only changing corne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 25 12  شماره 

صفحات  -

تاریخ انتشار 2009