Long-Term Stability of the NIST Standard Ultrasonic Source
نویسنده
چکیده
The National Institute of Standards and Technology (NIST) Standard Ultrasonic Source (SUS) is a system comprising a transducer capable of output power levels up to 1 W at multiple frequencies between 1 MHz and 30 MHz, and an electrical impedance-matching network that allows the system to be driven by a conventional 50 Ω rf (radio-frequency) source. It is designed to allow interlaboratory replication of ultrasonic power levels with high accuracy using inexpensive readily available ancillary equipment. The SUS was offered for sale for 14 years (1985 to 1999). Each system was furnished with data for the set of calibration points (combinations of power level and frequency) specified by the customer. Of the systems that had been ordered with some calibration points in common, three were returned more than once to NIST for recalibration. Another system retained at NIST has been recalibrated periodically since 1984. The collective data for these systems comprise 9 calibration points and 102 measurements spanning a 17 year interval ending in 2001, the last year NIST ultrasonic power measurement services were available to the public. These data have been analyzed to compare variations in output power with frequency, power level, and time elapsed since the first calibration. The results verify the claim, made in the instruction sheet furnished with every SUS, that "long-term drift, if any, in the calibration of NIST Standard Sources is insignificant compared to the uncertainties associated with a single measurement of ultrasonic power by any method available at NIST."
منابع مشابه
Long-Term Stability of the NIST Conical Reference Transducer
The National Institute of Standards and Technology (NIST) Conical Reference Transducer (CRT) is designed for purposes requiring frequency response characteristics much more uniform than those attainable with ultrasonic transducers conventionally used for acoustic emission (AE) nondestructive testing. The high performance of the CRT results from the use of design elements radically different fro...
متن کاملDevelopment of a New NIST Calibration Service Using the Comparison Method for Vacuum
Influencing the "injection barriers" into prototype molecular wires through metal-molecule Context: Many NIST customers using our vacuum calibration services spanning the pressure range from 0.65 Pa to 133 kPa (5 millitorr to 1000 torr) desire direct traceability to NIST but cannot justify the cost of calibration against relative to the NIST NIST Ultrasonic Interferometer Manometers (UIMs). The...
متن کاملThe Long Term Calibration Stability of Critical Flow Nozzles and Laminar Flowmeters
The National Institute of Standards and Technology (NIST) has performed calibrations of gas flowmeters using piston and bell provers for three decades. Most of the meters calibrated have been either critical flow nozzles or laminar flowmeters since these meter types are generally chosen as the working standards or transfer standards by other flow calibration laboratories. Often the same meters ...
متن کاملNew Photometric Calibration Programs at the National Institute of Standards and Technology
The NIST candela is maintained via standard photometers which have shown long-term stability better than 0.1% per year. The detector-based method has allowed us to reduce the uncertainties of calibrations and to expand the range of calibration capabilities. There have been several new developments in photometry at NIST. A high-illuminance calibration facility has been developed. Four temperatur...
متن کاملNew photometric calibration programmes at the National Institute of Standards and Technology
The National Institute of Standards and Technology (NIST) candela is maintained via standard photometers which have shown long-term stability of better than 0.1 % per year. The detector-based method has allowed us to reduce the uncertainties of calibrations and to expand the range of calibration capabilities. There have been several new developments in photometry at the NIST. A high-illuminance...