Direct frequency-comb spectroscopy of a dipole-forbidden clock transition in trapped 40Ca+ ions.

نویسندگان

  • Anne Lisa Wolf
  • Jonas Morgenweg
  • Jeroen C J Koelemeij
  • Steven A van den Berg
  • Wim Ubachs
  • Kjeld S E Eikema
چکیده

We demonstrate direct frequency-comb (FC) spectroscopy of the dipole-forbidden 4s(2)S(1/2)-3d(2)D(5/2) transition in trapped (40)Ca(+) ions using an unamplified FC laser. The excitation is detected with nearly 100% efficiency using a shelving scheme in combination with single-ion imaging. The method demonstrated here has the potential to reach hertz-level accuracy, if a hertz-level linewidth FC is used in combination with confinement in the Lamb-Dicke regime.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Absolute frequency measurement of the neutral 40Ca optical frequency standard at 657 nm based on microkelvin atoms

We report an absolute frequency measurement of the optical clock transition at 657 nm in 40Ca with a relative uncertainty of 7.5 x 10-15 , one of the most accurate frequency measurements of a neutral atom optical transition to date. The frequency (455986240494135.8 ± 3.4) Hz was measured by stabilizing a diode laser system to a spectroscopic signal derived from an ensemble of 106 atoms cooled i...

متن کامل

Laser Frequency and Time

The following two contributions in this volume are highlighting some remarkable recent developments at the interface between precision laser spectroscopy and ultrafast laser physics. After decades of struggle, we have finally found a practical method for measuring the frequency of light with extreme precision [1]. Femtosecond laser optical frequency comb synthesizers are opening exciting new pe...

متن کامل

Hertz-level measurement of the optical clock frequency in a single 88Sr+ ion.

The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium stan...

متن کامل

Frequency comparison of two high-accuracy Al+ optical clocks.

We have constructed an optical clock with a fractional frequency inaccuracy of 8.6x10{-18}, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser cool the Al+ ion and detect its quantum state. The frequency of the {1}S{0}<-->{3}P{0} clock transition is compared to that of a previously constructed Al+ optical clock with a statistical ...

متن کامل

Optical Clock Transition in Neutral Ytterbium

0031-9007= We report the direct excitation of the highly forbidden 6s2 S0 $ 6s6p P0 optical transition in two odd isotopes of neutral ytterbium. As the excitation laser frequency is scanned, absorption is detected by monitoring the depletion from an atomic cloud at 70 K in a magneto-optical trap. The measured frequency in 171Yb (F 1=2) is 518 295 836 591:6 4:4 kHz. The measured frequency in 173...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2011