Influence of Human and Bovine Substrate on the Microleakage of Two Adhesive Systems

نویسندگان

  • Karoline Guará Brusaca Almeida
  • Kristine Guará Brusaca Almeida Scheibe
  • Ana Emília Figuerêdo Oliveira
  • Cláudia Maria Coêlho Alves
  • José Ferreira Costa
چکیده

The aim of this study was to evaluate in vitro the marginal sealing of two adhesive systems and to analyze the influence of human and bovine substrates on marginal microleakage in enamel. Rectangular-shaped class V cavities (4 mm wide x 2 mm high x 2 mm deep) were made as follows: 8 cavities were prepared on the buccal and lingual surfaces of the human teeth with margins located on enamel and 16 cavities were prepared on the buccal surfaces of the bovine teeth. The cavities were randomly assigned to 4 groups of 8 cavities according to the adhesive system and substrate: G1--Prime & Bond 2.1 (Dentsply)/human substrate; G2--Adhese (Ivoclar/Vivadent)/human substrate; G3--Prime & Bond 2.1 (Dentsply)/bovine substrate; G4--Adhese (Ivoclar/Vivadent)/bovine substrate. The cavities were filled with microhybrid composite resin (Fillmagic) and after polishing/finishing procedures, the teeth were subjected to a thermocycling regimen of 500 cycles with 1-min immersions in water at 55 degrees+/-2 degrees C and 5 degrees+/-2 degrees C. Next, the teeth were coated with two layers of nail polish to within 1 mm of the margin, submerged in a 50% silver nitrate solution for 2 h, rinsed thoroughly in running tap and immersed in developing solution for 8 h. The restorations were bisected resulting in 16 specimens. Microleakage was observed under a stereomicroscope at x25 and recorded using four-point (0-3) scoring system. The data were analyzed statistically by the Mann Whitney U-test at 5% significance level. Leakage was present in all specimens and there was statistically significant difference between the adhesive systems. Adhese self-etching system showed significantly more leakage in both substrates (human--p= 0.0001 and bovine--p=0.0031). There was no statistically significant difference between human and bovine substrates for either of the adhesive systems based on different bonding mechanisms (Prime & Bond 2.1--p= 0.6923 and Adhese--p= 0.6109). Neither of the adhesive systems was capable to completely prevent microleakage and the self-etching system was more susceptible to microleakage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Thermocycling on Microleakage of New Adhesive Systems on Primary Teeth: An In-Vitro Study

Introduction: This study investigated the sealing ability of three different adhesives in primary bovine teeth. Methods: Facial and lingual class V cavities were prepared half in enamel and half in cementum, in 48 bovine primary mandibular incisors and randomly divided into three groups and each group divided to two subgroups. The tested adhesives were XPBond (XP), ClearfilS3 Bond (S3), and Xen...

متن کامل

Microleakage assessment of one- and two-step self-etch adhesive systems with ‎the low shrinkage composites

BACKGROUND AND AIM: Different studies evaluating one-step self-etch (SE) adhesive systems show contradictory findings, so the aim of this study was to compare the microleakage of one-step SE adhesive systems and CLEARFIL SE BOND (that serves as the “gold-standard” SE adhesive) with low shrinkage composites. METHODS: In this in vitro study, Class V cavities with the occlusal margin in enamel and...

متن کامل

In Vitro Microleakage of Class V Composite Restorations in Use of Three Adhesive Systems

Background and Aim: Microleakage is a drawback of composite restorations and it is more noticeable in dentinal walls. Despite advances in dentin bonding agents, no adhesive can completely eliminate microleakage and provide a hermetic seal. This study aimed to compare microleakage of three resin bonding agents namely a universal adhesive, two-step self-etch system and two-step total-etch system....

متن کامل

Effect of chlorhexidine solution on microleakage of pit and fissure sealants in permanent teeth with and without the use of fifth- and sixth-generation adhesive systems

Introduction: Due to concerns about histological caries and recurrent caries after the use of sealants, adhesive systems containing fluoride and antibacterial agents have been proposed. The aim of this study was to evaluate the microleakage of sealants after the use of antibacterial chlorhexidine solution on etched enamel with and without the use of fifth- and sixth-generation adhesive systems....

متن کامل

Microleakage comparison of three types of adhesive systems versus GIC-based adhesive in class V composite restorations

Background and aims: New dentin bonding agents and techniques have been developed to reduce microleakage and create higher bond strength. This in-vitro study compared the microleakage of three resin-based adhesives versus a GIC-based adhesive on class V composite restorations.  Materials and Methods: Class V cavities were prepared on the buccal surfaces of 72 sound premolars, randomly assigned ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2009